Morris MDE20291 Скачать руководство пользователя страница 3

This product refrigerant may be odorless.
Do not use any method to speed up the defrosting process or clean the frosted part.
Carefully read the instructions before operating the unit.
This appliance is  for indoor use  only and intended  for use  in a domestic  environment 
only. Any other use is  not recommended by the manufacturer and may  cause fire, 
electrical shocks or other injury to user or property.
Rating: This unit must be only connected to AC 220-240 V / 50 Hz earthed outlet.
Installation must be in accordance with regulations of the country where the unit is used.
If you are in  any doubt about the  suitability of your electrical supply  have it checked and,  

if necessary, modified by a qualified electrician.

This  dehumidifier  has  been  tested  and   is  safe  to  use.  However,  as   with  any  

electrical appliances - use it with care.
Disconnect the power plug from socket before dismantling, assembling or cleaning.
Avoid touching any moving parts of the appliance.

Never insert fingers, pencils or any other objects though the guard

This appliance is not intended  for use by persons (including children)  with reduced 
physical, sensory  or   mental  capabilities.  It  is   also  not  intended  for   use  by
those  with   a  lack  of experience and knowledge, unless they have been given 
supervision or  instruction concerning the use of the appliance by a person responsible for 
their safety.
Do not leave children unsupervised with this appliance.
Do not clean the unit by spraying it or immersing it in water.
Never connect the  unit to  an electrical outlet  using an  extension cord. If  a power  outlet 

is not available, one should be installed by a qualified electrician.

Never operate  this  appliance if  the  cord,  power adapter  or  plug  is damaged.  Ensure  
the power cord is not stretched or exposed to sharp object/edges.
A  damaged  power  supply cord  should  be  replaced  by  the  manufacturer  or  a

qualified electrician in order to avoid a hazard.

Any service  other  than regular  cleaning or  filter  replacement should  be performed  by  

an authorized service representative. Failure to comply could result in a voided warranty.
Do not use the appliance for any other purposes than its intended use.
Do not tilt the unit while in use. The unit is design to work only in vertical position.

This dehumidifier  must  always  be  stored and  transported  upright,  otherwise irreparable 

damage may  be caused  to the  compressor; if  in doubt we  suggest waiting  at least 24  
hours before starting the unit.

The room area of this product should be more than 4m

2

 when it is used, repaired and 

stored. 

This product needs to be used and stored where there is no fire source (such as electric 

heater at work, stove with open fire, etc.)

Important

SAFETY INSTRUCTIONS 

2

Содержание MDE20291

Страница 1: ......

Страница 2: ...Drainage 11 Care and Maintenance 11 Troubleshooting 13 This product is using the Environment friendly refrigerant R290 ODP value is 0 GWP value is 3 3 this refrigerant is tasteless and combustrible m...

Страница 3: ...een given supervision or instruction concerning the use of the appliance by a person responsible for their safety Do not leave children unsupervised with this appliance Do not clean the unit by sprayi...

Страница 4: ...r industrial environment where air composition is flammable Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills Do not operate and follow...

Страница 5: ...ogic MORRIS dehumidifiers feature an intelligent humidistat which is adjustable in increments of 5 from 40 80 RH insuring your room is not dried too much and power is not wasted Features Your dehumidi...

Страница 6: ...PARTS 5 GENRERAL DESCRIPTION 9 Filter 12 Power cord 11 Back cover 10 Continuous drain port 8 Water tank 7 Air inlet 6 Handle 5 Wheel 4 Lamp 3 Air outlet 2 Control panel 1 Oscillation louver...

Страница 7: ......

Страница 8: ...e a Delayed power on function the appliance is in stand by status USE key UP and DOWN to set the time period 1 24 hours The appliance will start once time reaches set value b Delayed power off functio...

Страница 9: ...speed High Fan Mode The fan will move the air around the room ensuring the entire air in the room is processed and the relative humidity correctly measured This mode gives you the ability to adjust th...

Страница 10: ...ion The water level control switch shuts off the dehumidifier when the tank is full or when the tank is removed or not replaced in the proper position Empty and replace to resume operation Auto Defros...

Страница 11: ...area you can begin by positioning the dehumidifier there and moving it to a more central location at a later date For the most effective use run your dehumidifier with external doors and windows kept...

Страница 12: ...water pump e g when draining a cellar to lift the water upwards Care and Maintenance Always shut off the unit and unplug from the mains before cleaning or performing any maintenance When it is not in...

Страница 13: ...e special cord storage rest at the back of the unit 4 Cover the unit and keep it in a dry place Frequently Asked Questions Why doesn t the dehumidifier seem to extract much water if the temperature is...

Страница 14: ...obstructions and restart the unit Ensure a distance of at least 20 cm between the unit walls Airflow seems weak Is filter dirty or clogged Please service the filters regularly as per user manual Unit...

Страница 15: ...e refrigerant is present Pre operation and during operation should be monitored in the area using an appropriate refrigerant monitor to ensure that the technicians are aware of the presence of potenti...

Страница 16: ...erformed on the most dangerous parts to prevent potential dangerous situations from occurring B 2 In the following maintenance of electrical components special care shall be taken not to cause mainten...

Страница 17: ...with inert gas cutting pipelines or welding Refrigerant should be recycled to a suitable storage tank The system should be purged with oxygen free nitrogen to ensure safety This process may need to b...

Страница 18: ...to be removed during maintenance or scrap It is recommended that the refrigerant be completely removed When loading the refrigerant into the tank use only a dedicated refrigerant tank It is necessary...

Страница 19: ...uld be disposed of separately from your household waste Please dispose of this equipment at your local community waste collection recycling centre In the European Union there are separate collection s...

Страница 20: ......

Отзывы: