TECHNICAL DATA
Model No.
MDD-86250
Rated Voltage
220-240V~ 50Hz
Dehumidify Capacity
10L/Day (20
o
C RH60%)
Max Rated Input Power
710W
Tank Capacity
6.5 litres
Air Volume
190 m
3
/h
Noise level
40 dB(A)
Net Weight
9.1 kg
All information provided is for reference only. Products specifications may change due to continuous
product development.
Disposal: Do not dispose this product as unsorted waste. Collection of such waste
must be handled separately as special treatment is necessary.
Water not
draining down
the hose
Hose is fitted for
continuous drainage but
the water still goes into the
tank
1. Negative air pressure in the
room is pulling the water back
into the dehumidifier overfl
2. Insert a 3mm hole into
the top of the tube 25mm
down from the spout.This will
introduce air into the tube and
balance out the air pressure
3. dirt is gather in the internal
tray.May need servicing
4,Rubber bung not placed in
the internal hole beyond tank
5,If fault persists then call the
service center
Dehumidifie
leaks water
onto the floo
Usually means that the
dehumidifier is not on a
level surface or that the
filter has not bee cleaned
often enough and dirt has
fallen into the internal tray
dehumidifie
1. check that the water bucket
is not cracked by filling it with
water and placing it on kitchen
paper on the kitchen side
2. check if filters are clea
3. if fault persists then call the
service center
Machine not
switching off
the heater
when desired
humidity
reached
Temperature and relative
h u m i d i t y s e n s o r t h a t
reads the room reading is
unable to read the correct
readings
1. clean the fil er and blow the
air sensor with a hover or hair
dryer on cold setting to clean
the sensor of fir
2. unplug the dehumidifier for
10 minutes to reset PCB and
turn back on
3. if fault persists then call the
service center
On pressing
power off fan
still works for
about 2-3
minutes and
switches off
Unit is drying internally
before going in off mode
Normal operation.Do not
interfere
Unit stops after
8 hrs
Unit is cooling down,will
restart after 30 minutes if
humidity is higher than set
target
Normal operation. Do not
interfere
Note: When the fault can not be solved by the solutions above,please contact service
center for help,do not attempt repairs
20
21
Your product is designed and manufactured with high quality materials
and components which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-
of-life,should be disposed of separately from your household waste.
Please dispose of this equipment at your local community waste
collection/ recycling centre.
DECLARATION OF CONFORMITY
Herewith, Amiridis-Savvidis S.A. states that this product, complies with
the requirements of below directives:
EMC-Directive: 14 / 30 / EU Low
Voltage Directive: 14/ 35 / EU
RoHS Directive: 11 / 65 / EU
The detailed declaration of conformity can be found at
www.morris.gr
In the European Union there are separate collection systems for used electrical and
electronic products. Please help us to conserve the environment we live in!
NOTICE ABOUT
RECYCLING