8
DATA HOLD BUTTON:
When this button is pushed, the display will show the last reading
and
"HOLD"
symbol will appear until pushing it again.
Data holding will be canceled automatically when the function
switch is rotated.
RELATIVE ZERO BUTTON:
For convenient readings, comparison & offset.
FUNCTION / POWER SWITCH:
Switch for changing the measurement function and power on and
off.
INPUT JACKS:
This meter has three input jacks that are protected against overload
to the limits except 10A. During use, connect the black test lead to
the
COM
jack and the red test lead as shown below:
Function
Red lead Connection Input limits
mV DC “+” 600V de or ac rms.
DCV/ACV
“+” 600V dc or ac rms.
Ω
/CONTINUITY/DIODE
“+”
250V dc or ac rms
CAP/Hz/%
“+”
250V dc or ac rms
µA/mA
“+”
400mA dc or ac rms.
A
“10A”
10A dc or ac rms.
MEASURING VOLTAGE
1. Connect the black test lead to the COM jack and red lead to the
“+” jack.
2. Set the function at mV DC DCV or ACV range to be used and
connect test leads across the source or load under measurement.
3. Read LCD display. The polarity of red connection will be
indicated when making a DC measurement.