MorrHeat MHB160 Скачать руководство пользователя страница 7

7

MorrHeat - Most Heat In The Industry 

MHB 80|160

Vitorond 100 with Aquastat or Hydrostat

Legend

BD

 | Boiler Drain

BTS

 | Boiler Temperature Sensor

BWR 

|

 

 Boiler Water Return

BWS 

| Boiler Water Supply

FGC 

|

 

Flue Gas Collar

SR 

| Safety Return

SS 

| Safety Suplly

BHL 

| Boiler High Limit

       (with outdoor reset module)

A Boiler Stand

B MorrHeat Burner

Boiler Model            

MHB80

MHB160

a.

13¾in

13¾in

b.

3in 

3in

c.

9½in

9½in

d.

4¼in

4¼in

e.

27¾in

27¾in

f.

32¼in

32¼in

g.

34¾in

34¾in

h.

39¾in

39¾in

k.

6½i

6½in

Dimensions

A

B

a

BWS

BHL

FGC

SR, BD

e

f

g

h

d

9¾"/250mm

5"/150mm

Width

Total Width

Содержание MHB160

Страница 1: ...Installation operation and service instructions 120v Manual Waste Oil Fired Boiler 80 160...

Страница 2: ...Table Of Contents Page 2 Product Informtion Page 3 Cutaway Section Page 4 Technical Data Page 5 MHB 80 160 Page 7 Clearances Page 8 Burner Dimensions Page 9 System Design Considerations Page 10 Insta...

Страница 3: ...ar Maximum heat extraction with triple pass design A F U E up to 84 Extremely durable cast iron heat exchanger for maximum reliability and service life Integrated stainless steel combustion changer in...

Страница 4: ...er and controls combination may not be exactly as illustrated A Special return water flow control injector B Eutectoplex heat exchanger surface of the special homogeneous grey cast iron C Vitoronic 10...

Страница 5: ...ing Height of boiler stand 29 in 20in 37in 37 in 22 in 39 in 50 in 59 in 9 in 34 in 20in 37in 42 in 22 in 39 in 50 in 59 in 9 in Weight Boiler Block Total Weight Boiler with Insulation Burner and Boil...

Страница 6: ...is not required and in the U S A 3 Measured flue gas temperature with combustion air temperature of 68 20 4 The vent pipe adaptor is not supplied with boiler models VR1 40 to VR1 63 For information re...

Страница 7: ...ler Water Supply FGC Flue Gas Collar SR Safety Return SS Safety Suplly BHL Boiler High Limit with outdoor reset module A Boiler Stand B MorrHeat Burner Boiler Model MHB80 MHB160 a 13 in 13 in b 3in 3i...

Страница 8: ...tion 1 Front service clearance 2 24 with Vitotronic control Boiler Model MHB80 MHB160 Rear in Sides in Flue in 6 0 9 6 0 9 6 150mm 6 5 165mm min 24 610mm min 9 230mm min 0 0mm min 6 150mm min 9 230mm...

Страница 9: ...Burner Specifications Voltage 120v Cycles 60Hz Total Operating Amperage Burner Only Amp 8 4 Voltage 120v Cycles 60Hz Total Operating Amperage Pump Assy Only Amps 2 1 BURNER ASSEMBLY PUMP ASSEMBLY Per...

Страница 10: ...th insulation We recommend consulting a reputable chimney installer for advice in project specific circumstances Barometric damper must be used Note Direct Vent exhaust system operates under a positiv...

Страница 11: ...Do not use automotive silicate base anitfreeze water mixturemay require a backflow preventer within the automatic water feed and influence components such an diaphragm expansion tanks radiation etc A...

Страница 12: ...30 USGM 11 5 14 3 General The schematics on the following pages are to be seen as guidelines only They futher do not display all system varieties safety devices or concepts possible Clearances A mini...

Страница 13: ...or well The function can be set to operate in automatic default or manual reset manual reset mode Do not disable this function it may be required by local codes Cooling season starts close valve v1 an...

Страница 14: ...40 40 35 31 25 13 20 4 18 3 14 7 12 10 10 14 9 16 8 18 7 19 6 21 5 23 4 25 3 27 2 28 1 30 00 32 1 34 2 36 3 37 4 39 5 41 6 43 7 45 8 46 9 48 10 50 12 54 14 57 16 61 18 64 20 68 25 77 30 88 35 95 40 1...

Страница 15: ...busing 1 x 04 Temperature and pressure gage 05 Reduction tee 2 x 5 06 Nipple 2 x 5 07 Reduction tee 2 x x 2 08 90 Street elbow 09 Nipple x 3 10 Pressure relief valve 30 psig 11 Reduction relief valve...

Отзывы: