Morphy Richards VC73410 MUK Скачать руководство пользователя страница 8

8

This function is ideal for cleaning underneath low
furniture.

1.

Separate the Lift Away canister

(32)

from the

motorised floor brush nozzle

(23)

by pressing the

Lift Away canister release button

(19)

on the side

of the Lift Away canister.

2.

Press the extension tube release button

(9)

and

pull the extension tube

(8)

up.

3.

Attach the end of the extension tube

(8)

to the

motorised floor brush nozzle

(23)

or Dust Away

Floor attachment

(30)

.

4.

Press the On/Off 3-position switch

(11)

to the “I”

position to turn the suction motor on.

NOTE: The rotating brush bar

(25)

will not rotate

in Lift Away canister mode.

5.

Gently press the motorised floor brush nozzle 

(23)

down with your foot while you grasp the handle

(1)

and tilt it back towards you. Tip the unit

backwards to access under low furniture.

When using the attachments, the suction may be
too powerful. Adjust the suction power by rotating
the suction adjustment collar

(3)

90°

anti-clockwise to open the valve to reduce
suction. Less suction may be required for
cleaning delicate areas and upholstery.

Rotate the collar clockwise to close the valve
when you need high suction and for vacuuming
floors.

If the cleaner overheats, a motor protection
thermostat will automatically switch the motor off.
If this happens, 

switch the cleaner off, unplug

from the power supply and leave the cleaner to
cool for at least 90 minutes

. Check the airways

for blockages, empty the dust canister and clean
the filters before restarting.

If the rotating brush bar

(25)

becomes jammed, a

safety cut-out will stop the brush and the
motorised floor brush indicator light

(24)

will

change from green to red. If this happens, 

switch

off and unplug the product

. Disconnect the

motorised floor brush nozzle and carefully remove
the blockage.

WARNING: Always unplug the vacuum cleaner
from the mains supply before undertaking any
of the following maintenance procedures.

Empty the dust canister

(13)

regularly even if it

does not look full, this will maintain the
performance.

1.

Unplug the cleaner from the mains switch.

2.

Undo the dust canister release latches

(16)

on

each side of the Lift Away canister

(32)

by lifting

them up and outwards.

3.

Remove the dust canister from the motor base

(18)

.

Maintenance

Safety cut-outs

Emptying the dust canister

Cleaning under furniture in
Lift Away canister mode

Adjusting suction power

Certain
models
only

Suction

 

Release

 

Collar

VC73410MUK Rev4_Instruction Book  31/10/2012  11:18  Page 8

Содержание VC73410 MUK

Страница 1: ... and Ireland customers only Bagless Upright Vacuum Cleaner www morphyrichards co uk blog For competitions product hints and tips and more join us at www facebook com morphyrichardsuk loveyourmorphy Please read and keep these instructions for future use VC73410MUK Rev4_Instruction Book 31 10 2012 11 18 Page 1 ...

Страница 2: ...tances Never pick up acids asbestos or asbestos dust Never touch the plug or cable with wet hands Do not immerse cord plug or cleaner in water or other liquid The appliance must never be left running unsupervised Location Do not use or keep this product outside Do not store the appliance near hot surfaces eg ovens or heating appliances Mains cable If the supply cord is damaged it must be replaced ...

Страница 3: ...Dust Away cleaning cloth certain models only Cleaning under furniture in Lift Away canister mode Adjusting suction power Safety cut outs Maintenance Emptying the dust canister Maintenance filters Hose blockages Cleaning the motorised floor brush Cleaning the turbo nozzle certain models only Storage Contact us Guarantee Contents 2 2 4 5 5 6 6 7 7 8 8 8 8 8 9 10 10 11 11 11 12 VC73410MUK Rev4_Instru...

Страница 4: ...ift Away canister release button 20 Exhaust filter cover 21 Floor brush nozzle tube 22 Floor brush nozzle hose 23 Motorised floor brush nozzle 24 Motorised floor brush indicator light 25 Rotating brush bar 26 Extra long crevice tool certain models only 27 Crevice tool certain models only 28 Dusting brush 29 Turbo nozzle certain models only 30 Dust Away floor attachment certain models only 31 Dust ...

Страница 5: ...til you hear the two pieces click into place NOTE The motorised floor brush nozzle must be fully locked in place to ensure the electrical connection is made 2 Attach the end of the extension tube 8 to the tube on the back of the Lift Away canister 32 until it clicks in to place 3 Slide the accessory holder 5 in to position opposite the upper cord wrap 6 over the extension tube 8 Align the tab and ...

Страница 6: ...MPORTANT The motorised floor brush indicator light 24 will illuminate green when the motorised floor brush is on or red if there is a blockage or a jam see Safety Cut Outs section on page 8 Using in Lift Away canister mode 2 1 This function is ideal for cleaning stairs curtains upholstery and hard to reach places 1 Separate the Lift Away canister 32 from the motorised floor brush nozzle 23 by pres...

Страница 7: ...leaning cloth to clean dry bare floor surfaces Do not use to clean damp floors or wet sticky messes 1 3 2 The Dust Away cleaning cloth 31 attaches to the Dust Away floor attachment 30 with four velcro pads Slip two of the tabs between the suction nozzle and the duster base and attach them to the front fasteners on the base Pull the other two tabs tightly around to the back fasteners on the base Fo...

Страница 8: ...and for vacuuming floors If the cleaner overheats a motor protection thermostat will automatically switch the motor off If this happens switch the cleaner off unplug from the power supply and leave the cleaner to cool for at least 90 minutes Check the airways for blockages empty the dust canister and clean the filters before restarting If the rotating brush bar 25 becomes jammed a safety cut out w...

Страница 9: ...d push down to lock The guarantee may be invalidated if the motor is damaged due to using the appliance without the filters installed not cleaning the filters or not replacing damaged filters Cleaning the pre motor filters To maintain suction the pre motor filters must be cleaned each time the dust canister 13 is emptied 1 Remove the dust canister 2 Pull the 2 filters out from the top of the motor...

Страница 10: ...side for blockages Also inspect inside the suction ducts on the vacuum cleaner 1 Press the On Off 3 position switch 11 to the O position to turn the vacuum off and unplug the power cord from the mains outlet 2 Separate the Lift Away canister 32 from the motorised floor brush nozzle 23 by pressing the Lift Away canister release button 19 on the side of the Lift Away canister then gently hold the mo...

Страница 11: ...k 1 Convert your vacuum back to upright vacuum mode 2 Rotate the upper cord wrap 6 to its upright position and coil the power cord loosely around the upper 6 and lower 17 cord wraps 3 Store the dusting brush 28 and the crevice tool 26 27 depending on model on the mounts on the accessory holder 5 Helpline If you are having a problem with your appliance please call our Helpline as we are more likely...

Страница 12: ...ut may have activated If for any reason this item is replaced during the 2 year guarantee period the guarantee on the new item will be calculated from original purchase date Therefore it is vital to retain your original till receipt or invoice to indicate the date of initial purchase This appliance is intended for domestic use only Misuse or use for commercial or any other purpose will render the ...

Отзывы: