Morphy Richards 70048 Скачать руководство пользователя страница 13

13

Your three-year 
guarantee

• 

It is important to retain the retailers receipt as 
proof of purchase. 

Staple your receipt to this back 

cover for future reference.

Please quote the following information if the product 
develops a fault. These numbers can be found on the 
base of the product.

Model no.                                    Serial no.

   All Morphy Richards products are individually tested 
before leaving the factory. In the unlikely event of 
any appliance proving to be faulty within 28 days 
of purchase it should be returned to the place of 
purchase for it to be replaced.

   If the fault develops after 28 days and within 36 
months of  the original purchase date please contact 
our helpline quoting the model number and serial 
number. Repair or replacement is subject to the exclu-
sions (1-6) set out below .
 
   If you suspect a fault, follow the simple checks de-
tailed below before returning the appliance or calling 
the helpline.

• Check the dust bag and filters for blockages. 
• Check the hose and tubes for blockages. 
• Check the plug is firmly in the socket and the supply  
  is switched on. 
• Make sure the socket is working by trying another  
  appliance.
   If for any reason this item is replaced during the 
three-year guarantee period, the guarantee on the 
new item will be calculated from original purchase 
date. Therefore it is vital to retain your original receipt 
or invoice to indicate the date of initial purchase.

   To qualify for the three-year guarantee the appliance 
must have been used according to the manufacturers 
instructions. 
   Morphy Richards shall not be liable to replace or 
repair the goods unter the terms of the Grarantee 
where:

1. The fault has been caused or is attributable to  
    accidental use, mis-use, negligent use or used  
    contrary to the manufacturers recommen- 
    dations or where the fault has been caused by  
    power surges or damage caused in transit.

 

2. The appliance has been used on a voltage  
   supply other than that stamped on the products. 
3. Repairs have been attempted by persons other  
    than our service staff (or authorised dealer). 
4. Where the applinace has been used for hire  
    purposes or non-domestic use. 
5. The guarantee excludes consumables such as  
    bags and filters. 

6. Morphy Richards are not liable to carry out any  
    type of servicing work, under the guarantee.
   This guarantee does not confer any rights other than 
those eypressly set out above and does not cover any 
claims for consequential loss or damage. This guaran-
tee is offered as an additional benefit and does not 
affect your statutory rights as a consumer.

• This guarantee is valid in the UK and Ireland only.

For electrical products sold within the 
European Community. At the end of the 
electrical products useful life it should not 
be disposed of with household waste.
Please recycle where facilities exist.
Check with your Local Authority or retailer 
for recycling advice in your country.

The After Sales Division
Morphy Richards Ltd

Mexborough, South Yorkshire,
England, S64 8AJ

Helpline (office hours)
UK 0870 060 2604
Republic of Ireland 1800 409119

Morphy Richards products are intended for house-
hold use only.
Morphy Richards has a policy of continuous impro-
vement in product quality and design. The company, 
therefore reserves the right to change the specifica-
tion of its models at any time.

For details of other products in the Morphy Richards range please see our website . . .

Содержание 70048

Страница 1: ...egularly or replaced to allow air through the appliance Blockages Check the nozzle tubes and hose for blockages Safety cut out If the product switches itself off during use refer to page 13 for instructions Read these operating instructions and keep them in a safe place VC70048MUK Rev 1 For replacement parts help with using your Morphy Richards product problems and lots more contact us by phone or ...

Страница 2: ...2 8 17 1 7 5 6 2 3 4 11 20 18 9 10 16 15 11 19 A 12 13 14 ...

Страница 3: ...3 B1 B2 B3 B4 B5 B6 B7 B B8 ...

Страница 4: ...4 B13 B10 B11 1 3 2 B9 B12 B15 B14 ...

Страница 5: ...5 B16 B18 B19 B17 B21 B22 B20 B23 ...

Страница 6: ...6 B24 B25 B26 B27 ...

Страница 7: ... power cord full out before use If the power cord is damaged it must be completely replaced along with the cable cylinder by custo mer service Do not vacuum up ashes large fragments of glass sharp objects or any liquids Don t vacuum up any toner dust which is used in printers and copiers for example because it is electrically conductive In addition it is possible that it will not be completely fil...

Страница 8: ...pliance in damp rooms Never use the appliance without a filter Make sure that the filter is inserted into the appliance correctly When using the appliance make sure that no hair clothing or members are drawn in Keep the vacuum cleaner away from heat sources such as radiant heaters ovens and so on Electrical Requirements Check that the voltage onthe rating plate of yourappliance corresponds withyou...

Страница 9: ...with your foot or hand to wind up the cable WARNING When rewinding always hold the plug B5 Make sure that the power control is set all the way to the left to Min To start the motor press the On Off switch B6 Now turn the power control to the right until the desired power setting has been reached Work with consistent speed when vacuuming In the process it is unnecessary to apply additional pressure...

Страница 10: ...nser ted into the holder for the tube in the storage position on the bottom of the appliance B14 Changing the vacuum cleaner bag The dust bag must be changed if the suction power is diminished or in case the Dust bag full indicator is on continuously Also check whether the vacuum hose tube or nozzle is blocked Press the unlocking button of the dust compartment lid and fold down the dust compartmen...

Страница 11: ...lter away from the cleaner B24 The filter configuration varies depending on the appliance model Pull the HEPA exhaust filter up and out of the holder Clean the HEPA exhaust filter by banging it out or with a soft brush Afterwards put the HEPA exhaust filter back into the appliance The HEPA exhaust filter must be replaced with a new one after approx 50 hours of normal operation B25 The filter confi...

Страница 12: ...of the dust bag will become clogged Then the change dust bag display will show full even if the dust bag is not yet full The dust bag must then be changed since the suction power has been reduced by the plugged pores However if you vacuum up a great deal of hair carpet or wool fluff etc then the change dust bag display may only respond when the dust bag is already bulging full Overheating protecti...

Страница 13: ...e goods unter the terms of the Grarantee where 1 The fault has been caused or is attributable to accidental use mis use negligent use or used contrary to the manufacturers recommen dations or where the fault has been caused by power surges or damage caused in transit 2 The appliance has been used on a voltage supply other than that stamped on the products 3 Repairs have been attempted by persons o...

Отзывы: