Morita Tri auto mini Скачать руководство пользователя страница 1

Cordless endodontic treatment motorized handpiece

Tri Auto mini

(TR-CM)

Operation Instructions

Содержание Tri auto mini

Страница 1: ...Cordless endodontic treatment motorized handpiece Tri Auto mini TR CM Operation Instructions...

Страница 2: ...2 Operation 12 Basic Operation 12 Memory Settings 13 Memory Settings Primary Functions 13 Memory Settings Additional Operation Settings 14 Memory Settings Other Settings 15 Restore Default Memories 16...

Страница 3: ...N 1394779 CN DESIGN APPLN 201030166890 6 Thank you for purchasing the Tri Auto mini For optimum safety and performance read this manual thoroughly before using the unit and pay close attention to warn...

Страница 4: ...oided by foreseeing the possibility of danger and operating the unit in accordance with the manufacturer s recommendations First thoroughly read all precautions and instructions pertaining to safety a...

Страница 5: ...RITA MFG CORP and other than in their original condition 5 operating the equipment in ways other than the operating procedures described in this manual or resulting from the safety precautions and war...

Страница 6: ...ce electrical noise Do not use this instrument on patients who have a pacemaker or an Implantable Cardioverter Defibrillator ICD It could cause the pacemaker or the Implantable Cardioverter Defibrilla...

Страница 7: ...automatically reverses its rotation if the torque load exceeds the set value to reduce the risk of jamming Slow Down The file slows down as torque increases The file slows down as it approaches the a...

Страница 8: ...lus and Minus Switches Power Supply Cord Charge LED orange Power LED green Charger Motor Handpiece Charger Switch Parts Identification and Accessories Battery Inside motor handpiece Transmission Cable...

Страница 9: ...ight get wet Usage Operation Conditions for the main unit and AC adapter Charge the battery as soon as the battery power indicator gets down to its last bar If the orange charge LED goes off immediate...

Страница 10: ...s frequently Contra Angle Motor Handpiece Line up the marks Approx 290 Do not force the contra angle to rotate beyond its limit The rotation range of the contra angle is about 290 Set it so that it re...

Страница 11: ...cted to the Root ZX mini Never use deformed or damaged files Give the file a light tug to confirm it is securely held in place If the file is not securely placed it could come out and injure the patie...

Страница 12: ...y to check Nickel titanium file may suddenly snap depending on the curvature and shape of the canal stop using the file if you notice or feel anything amiss Files will eventually break due to metal fa...

Страница 13: ...motor Press Main switch again The Torque Display will appear If you hold the Main Switch down when you start the motor it will run only while the switch is held down and stop when the switch is relea...

Страница 14: ...0 1 5 2 0 2 5 and 3 0 Ncm This function can also be turned off TRL torque reverse less Rotation Direction Fwd Forward Rev Reverse Standby Display Rotation Direction Speed Torque Reverse These functio...

Страница 15: ...Plus or Minus switch The display will go back to the standby display if 5 seconds factory setting elapses without a switch being pressed Torque Slow Down When this is turned on the motor will slow dow...

Страница 16: ...Change Return to Standby Time Beeper Volume Press Plus or Minus switch to set beep volume used for switch operation and alarms at Off Low or Big Auto Power Off Time The time lapse for automatic shut...

Страница 17: ...s or press the Main switch to cancel the operation 3 Wait unit the Finished display appears and then press the Main switch to go to the standby display Take care not to injure your fingers when insert...

Страница 18: ...used to secure the file electrode Take out the black screw and remove the cap that covers the elctrode installation area Usage Operation with the Root ZX mini Electrode Site Cap File Electrode Instal...

Страница 19: ...s without holding the file release button down will damage the chuck Use caution when inserting and removing files to avoid injury to fingers Make sure the file goes all the way in Give the file a lig...

Страница 20: ...up when you do this Make sure the plugs go straight in After insertion give plugs a light tug to make sure they are securely connected Otherwise data may not be transmitted acurately Do not bump the...

Страница 21: ...not suitable for measurement Accurate measurement is not always possible especially in cases of abnormal or unusual root canal morphology always take an X ray to check the measurement results If the...

Страница 22: ...single sustained beep will sound when this happens If the unit is set for Apical Reverse the motor will run backwards after it stops If the load on the file exceeds the setting for torque reverse the...

Страница 23: ...er goes all the way to its end and there are no segments that do not light up Refer to page 17 for how to install the new file electrode Take out the screw Take out the old file electrode Pull the fil...

Страница 24: ...r each patient Recommended 134 C 273 2 F for at least 5 minutes inside a sterilization pouch or 121 C 249 8 F for at least 35 minutes inside a sterilization pouch Minimum drying time after sterilizati...

Страница 25: ...ther components These chemicals could damage deform or discolor plastic and metal Use extra caution to avoid spilling formalin cresol FC and sodium hypochlorite as they are quite strong Wipe up any ch...

Страница 26: ...2 for how to replace the file electrode Connect the new battery and put it in Replace the cover and its screw Turn power off Remove the screw and slide the battery cover off Take out the old battery a...

Страница 27: ...45 C 14 to 113 F Realtive Humidity 10 to 85 RH without condensation Atmospheric Pressure 700 to 1 060 hPa Do not expose to direct sunlight frequently or for long times If the unit has not been used fo...

Страница 28: ...pressed while the Select switch is being held down 3 Check that pressing the Plus and Minus switches changes the memory number from M1 through M6 4 Check that the settings for each memory can be chan...

Страница 29: ...ld be recycled Metal parts of the equipment are disposed as scrap metal Synthetic materials electrical components and printed circuit boards are disposed as electrical scrap Material must be disposed...

Страница 30: ...setting turned off Turn Linked Function setting on Is Auto Start Stop turned off Turn Auto Start Stop setting on Has the meter gone past the Flash Bar Set the Apical Stop or Reverse for Reverse REV M...

Страница 31: ...oard may be defective Micromotor changes speed on its own Is Apical Slow Down setting tuned on When this is turned on the motor slows down as the file approaches the apex Refer to page 14 for how to t...

Страница 32: ...itting Length of Shank 9 0 mm Maximum Overall Length of Rotary Instrument 28 0 mm Type of Shank Type 1 according to ISO 1797 1 Type of Coupling TR CM coupling It can be used only with TR CM motor hand...

Страница 33: ...equipment cannot be disposed of as unsorted municipal waste within the European Union Follow local regulations for disposal Attention consult accompanying documents Manufacturer Type BF applied part C...

Страница 34: ...nt guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 2 4 6 kV contact 2 4 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material t...

Страница 35: ...hould be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency...

Страница 36: ...ications equipment transmitters and the TR CM as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance...

Страница 37: ...wn should be devised to protect the safety of the patient in case any abnormalities in the equipment or the patient are observed 4 Make sure the patient does not handle or manipulate the equipment 5 I...

Страница 38: ......

Страница 39: ......

Страница 40: ...PUB M9826 EN 4 Printed in Japan...

Отзывы: