COOLANT UNIT PROBLEMS
1
1
7
ɹ˂ʳʽʒʰʕʍʒɁႱࢠ
COOLANT UNIT PROBLEMS
7-1
‘EX1557
ᴥɹ˂ʳʽʒํᦀȟͲ˩ȪɑȪȲᴦ
’
‘EX1557 (COOLANT FLOW TOO LOW)’
ɹ˂ʳʽʒʟʷ˂ʃɮʍʋᴥɴʡʁʱʽᴦɥଃᢐȪȹȗɞൡ
ಽȺɂǾɹ˂ʳʽʒɁํᦀȟͲ˩ȬɞȻႱࢠɥ೫ᅺȪǾɬ
ʳ˂ʪȟᄉႆȪɑȬǿɬʳ˂ʪȟᄉႆȬɞȻ˿ᢉɁوᢆȟϦ
ඨȪǾˢϦඨৰȻȽɝɑȬǿ͏˩ɁቛɥՎྃȪǾɹ˂ʳ
ʽʒᥓከȾɟɗᝇɑɝȟȽȗȞǾȝɛɆյʰʕʍʒȾႱࢠ
ȟȽȗȞɥᆬᝓȪȹȢȳȨȗǿ
With machines equipped with the coolant flow switch, if the
coolant flow drops the switch detects an abnormality of the
coolant flow level and an alarm occurs. When an alarm occurs,
spindle rotation stops and the machine is set in the feed hold
status. Refer to the following chapter and check for coolant
pipe leakage, coolant clogging or coolant unit abnormalities.
1.
1
1.
2.
2.
“COOLANT COOLING UNIT (OPTION)” (page 138)
3.
3.
“When Coolant is Not Supplied” (page 185)
7-2
‘EX0578
ᴥɹ˂ʳʽʒɴɮʵȟ˪ᠴȪȹȗɑȬᴦ
’
‘EX0578 (COOLANT OIL LEVEL LOW)’
ɹ˂ʳʽʒʟʷ˂ʒʃɮʍʋᴥɴʡʁʱʽᴦɥଃᢐȪȹȗɞ
ൡಽȺɂɹ˂ʳʽʒɁᦀȟ˪ᠴȪȹȗɞȻႱࢠɥ೫ᅺȪɬ
ʳ˂ʪȟᄉႆȪɑȬǿɬʳ˂ʪȟᄉႆȬɞȻ˿ᢉɁوᢆȟϦ
ඨȪǾˢϦඨৰȻȽɝɑȬǿ͏˩ɁቛɥՎྃȪǾɹ˂ʳ
ʽʒᥓከȾɟɗᝇɑɝȟȽȗȞǾȝɛɆյʰʕʍʒȾႱࢠ
ȟȽȗȞɥᆬᝓȪȹȢȳȨȗǿ
With machines equipped with the coolant float switch (option),
if the coolant level becomes too low the switch detects an
abnormality of the coolant float level and an alarm occurs.
When the alarm occurs, spindle rotation stops and the machine
is set in the feed hold status. If this happens, refer to the
chapter indicated below and check for coolant pipe leakage,
coolant clogging and coolant unit abnormalities.
1
1
“Replenishing Coolant” (page 85)
2
าᜤ
2
NOTE
ɹ˂ʳʽʒᛃፈऻǾ
@
ᴥʴʅʍʒᴦ
ɷ˂ɥઃȪȹȢȳȨȗǿ
@
ᴥʴ
ʅʍʒᴦ
ɷ˂ɥઃȪȹɕɬʳ˂ʪȟțȽȗکնɂࣷᇋɿ˂ʝʃᩌ
ȾȧᣵፅȢȳȨȗǿ
Note: Press the
@
(RESET)
key after replenishing coolant. If the alarm
is not reset after pressing the
@
(RESET)
key, contact the Mori Seiki
Service Department for assistance.
7-3
ɹ˂ʳʽʒȟࣂȾȕɈɟҋɞȻȠ
When Coolant Spills on the Floor
ɹ˂ʳʽʒȟࣂȾȕɈɟҋɞکնɂǾ͏˩ɁȗȭɟȞɁίަ
ཟ೫ȟᤛҒȾஃȨɟȹȗȽȗժᑤॴȟȕɝɑȬɁȺǾ॒ᛵ
Ⱦख़ȫȹஃȪȹȢȳȨȗǿ
If coolant spills on the floor, one or both of the following
maintenance inspections may not have been properly
performed. Perform the following inspections as required.
1.
1
1.
“Cleaning Coolant Tank and Filter (Chip Conveyor Right
Side Discharge Specifications)” (page 86)
“Cleaning Coolant Tank and Filter (Chip Conveyor Rear
Discharge Specifications)” (page 87)
2.
2.
“Adjusting Coolant Discharge Rate” (page 89)
7-4
ɹ˂ʳʽʒȟҋȽȗȻȠ
When Coolant is Not Supplied
ɹ˂ʳʽʒվҋɁႱࢠɂǾɹ˂ʳʽʒʧʽʡȟͽӦȪȹȗɞ
ɁȾɹ˂ʳʽʒȟҋȽȗکնȻǾɹ˂ʳʽʒʧʽʡȟͽӦȪ
ȹȗȽȗکնȻȾґȤɜɟɑȬǿ͏˩ȾᆬᝓȻेகศɥᇉ
ȪɑȬǿ
Problems related to the supply of coolant can be divided into
two categories; cases when coolant is not supplied when the
coolant pump is operating; and cases when the coolant pump
is not operating. The confirmation and recovery procedures for
both cases are outlined below.
Содержание NL1500/500
Страница 8: ......
Страница 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Страница 10: ......
Страница 19: ...FOR SAFE MACHINE OPERATION...
Страница 50: ......
Страница 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Страница 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Страница 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Страница 232: ......
Страница 240: ......
Страница 242: ......