Technical Setting
Digibook 300
www.morgana.co.uk
11
4)
Check of the spine preparation
unit height on the right side.
On the right side of the milling disk, the
distance between BlockM plane and the
upper surface of cutting knives must be
(X+0.3) ±0.1 mm. If it is not, turn the 4
adjustment screws; see point 4.1.
Fig. 2.7
4A) To access the adjustment screws,
remove the mobile guard and the
Plexiglas® inspection panel (Fig. 2.8).
Slightly loosen the fixing screws and turn
the adjustment screws so as to move the
unit to the desired height. Measure again
using the depth gauge; then tighten the
side fixing screws. After fixing the unit,
return the Plexiglas® panel and mobile
guard to their positions.
Fig. 2.8
Fig. 2.9
5)
Test of the back-cut unit block.
The distances of the back-cut unit block
(Fig. 2.10) must be:
A= 0.15 mm
B= 1.0 mm
Check the measurements using the
thickness gauge.
Fig. 2.10