background image

Function

Description

Annotation

No node ID

The Z-Wave Controller does not allocate 
a node ID to the Switch.

LED 2-second on, 2-
second off

Inclusion

1. Put your Z-Wave controller into

inclusion mode by following the 
instructions provided by the 
controller manufacturer.

One press one flash LED

2. Pressing INCLUDE_BUTTON three

times within 2 seconds will enter 
inclusion mode.

Exclusion

1. Put your Z-Wave controller into

exclusion mode by following the 
instructions provided by the 
controller manufacturer.

One press one flash LED

1.

Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
exclusion mode.

3. Node ID has been excluded.

LED 0.5s On, 0.5s Off 
(Enter auto inclusion)

Reset

1.

Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
inclusion mode.

Use this procedure only in 
the event that the primary 
controller is lost or 
otherwise inoperable.

2.

Within 1 second, press On/Off
button again for 5 seconds.

3.

IDs are excluded.

LED 0.5s On, 0.5s Off 
(Enter auto inclusion)

Association

1. The 

iZOFC22

 is an always listening

Z-Wave device, so associations 
be added or removed by a controller 
at any time. 

Or  If your controller requires to have 

the 

iZOFC22

 send a 'node information

frame' or NIF for associations, 
pressing the On/Off button three times 
within 2 seconds will cause the 

iZOFC22

 to send its NIF.

LED one press one flash

2. There are 3 groups for the switch

Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node 

ID allocated by Z-Wave Controller means exclusion.

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

Sometimes people are not easy to execute exclusion or inclusion especially when 

iZOFC22

 already installed in a wall box. To solve this issue, 

iZOFC22

 support 

a

special feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or 
Association” at the first 3 minutes when first time connect to main power.

 

 

 

LED Indication

 

To distinguish what mode the switch is in, view from the LED for identification. 

State Type

 

LED Indication

 

Normal

 

Whatever we switch On and off of the 

iZOFC22

 by S1 S2 or On/

Off button or RF command, the LED will lights up 1 second and 
then off.

 

No node ID

 

Under normal operation, when the Switch has not been allocated a 
node ID, the LED flashes on and off alternately at 2-second 
intervals. By pressing S1 S2 or On/Off button, it will stop flashing 
temporarily. 

 

Learning

 

When 

iZOFC22

 is in learning mode, LED flashes on and off

alternately and repeatedly at 0.5 second intervals.

 

Overload

 

When overload state occurs, the Switch is disabled of which LED 
flashes on and off alternately at 0.2 second intervals. Overload 
state can be cleared by disconnect and reconnect the Switch to 
the main power

 

Choosing a Suitable Location 

1.

Do not locate the Switch facing direct sunlight, humid or dusty place.

2.

The suitable ambient temperature for the Switch is 0°C~40°C.

3.

Do not locate the Switch where exists combustible substances or any
source of heat, e.g. fires, radiators, boiler etc.

4.

After putting it into use, the body of Switch will become a little bit hot of
which phenomenon is normal.

www.mordomus.com

Содержание iZOFC22

Страница 1: ...ever disconnect and re connect the Module will reset its overload condition to normal status Adding to Z WaveTM Network In the front casing there is an on off button with LED indicator below which is used to toggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It impl...

Страница 2: ...D allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller Sometimes people are not easy to execute exclusion or inclusion especially when iZOFC22 already installed in a wall box To solve this issue iZOFC22 support a special feature that can use S1 or S2 to execute exclusion inclusion Reset or Association at the fi...

Страница 3: ... illuminating but cannot control the ON OFF Switch of the load attached Check if the load connect into the Switch has its own ON OFF switch Set the ON OFF switch of the load attached to ON The Switch LED illuminating but the Detector cannot control the Switch 1 Not carry out association 2 Same frequency interference 1 Carry out association 2 Wait for a while to re try LED keep flashing but cannot ...

Страница 4: ...Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee th...

Отзывы: