2
Function
Description
Annotation
No node ID
The Z-Wave Controller does not allocate
a node ID to the Switch.
LED 2-second on, 2-
second off
Inclusion
1. Put your Z-Wave controller into
inclusion mode by following the
instructions provided by the
controller manufacturer.
One press one flash LED
2. Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
inclusion mode.
Exclusion
1. Put your Z-Wave controller into
exclusion mode by following the
instructions provided by the
controller manufacturer.
One press one flash LED
1.
Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
exclusion mode.
3. Node ID has been excluded.
LED 0.5s On, 0.5s Off
(Enter auto inclusion)
Reset
1.
Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
inclusion mode.
Use this procedure only in
the event that the primary
controller is lost or
otherwise inoperable.
2.
Within 1 second, press On/Off
button again for 5 seconds.
3.
IDs are excluded.
LED 0.5s On, 0.5s Off
(Enter auto inclusion)
Association
1. The
iZOFC22
is an always listening
Z-Wave device, so associations
be added or removed by a controller
at any time.
Or If your controller requires to have
the
iZOFC22
send a 'node information
frame' or NIF for associations,
pressing the On/Off button three times
within 2 seconds will cause the
iZOFC22
to send its NIF.
LED one press one flash
2. There are 3 groups for the switch
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
Sometimes people are not easy to execute exclusion or inclusion especially when
iZOFC22
already installed in a wall box. To solve this issue,
iZOFC22
support
a
special feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or
Association” at the first 3 minutes when first time connect to main power.
LED Indication
To distinguish what mode the switch is in, view from the LED for identification.
State Type
LED Indication
Normal
Whatever we switch On and off of the
iZOFC22
by S1 S2 or On/
Off button or RF command, the LED will lights up 1 second and
then off.
No node ID
Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or On/Off button, it will stop flashing
temporarily.
Learning
When
iZOFC22
is in learning mode, LED flashes on and off
alternately and repeatedly at 0.5 second intervals.
Overload
When overload state occurs, the Switch is disabled of which LED
flashes on and off alternately at 0.2 second intervals. Overload
state can be cleared by disconnect and reconnect the Switch to
the main power
Choosing a Suitable Location
1.
Do not locate the Switch facing direct sunlight, humid or dusty place.
2.
The suitable ambient temperature for the Switch is 0°C~40°C.
3.
Do not locate the Switch where exists combustible substances or any
source of heat, e.g. fires, radiators, boiler etc.
4.
After putting it into use, the body of Switch will become a little bit hot of
which phenomenon is normal.
www.mordomus.com