iThink – Management Unit
Hardware: V1
Firmware: V1
1.
GENERAL FEATURES:
Communication:
MDiBus (Half-duplex) e RS232 (Full-
duplex);
MDiBus control outputs:
3000 inputs or outputs;
Control outputs direct in module:
8 open-collector outputs.
Inputs:
8
digital inputs, configurable for reading keys (3
pressing types), reading security equipment (PIR, Gas, Fire)
status reading and meter.
Connectivity:
1 X LAN (RJ45), 2 X USB, 1 X audio Out 2
channels, 8 digital inputs + 8 digital outputs, 1 X MDiBus
(RJ45), Bluetooth, WLAN;
Applications:
Processing center for Mordomus iThink
modules
;
Installation:
Control panel in DIN rail or fastening by 4 non-
standard screws
.
2.
GENERAL SPECIFICATIONS:
Mains Voltage:
12VDC;
Consumption:
6A @ 12VDC;
Communications:
GSM Quad-Band and USB;
Storage Temperature:
-10ºC a 60ºC;
Operating Temperature:
10ºC a 50ºC;
Maximum humidity:
80% non-condensing;
Physics Specifications:
Dimensions:
154mm X 110mm X 60mm, DIN rail mounting
(9 modules);
Self-extinguishing plastic box UL-94 V0;
Level Protection:
IP20, for indoor use;
Output Specifications:
Rated current:
0.5A;
Type:
Open-Collector.
Inputs Specifications:
- Rated Voltage in the Inputs:
- Digital:
5VDC low voltage;
-
Maximum permissible resistance of the
contacts connected to the input
:
50Ω.
Directives:
-
Electromagnetic Compatibility Directive / EMC
Directive
2014/30/EU
3.
COMPATIBILITY:
Compatibility with Mordomus software:
Mordomus iThink
V2017 or higher.
The GSM communicator of the iThink module complies with
the communications standards: CE, GCF, China RTE, R &
TTE, PTCRB, AT & T, FCC, IC.
4.
SECURITY:
Before making any connections, read these instructions
carefully.
Radio frequency transmitters such as the iThink module's
GSM communicator may interfere with the correct functioning
of under-protected medical equipment. Before using the
iThink module GSM near medical equipment, you should
consult the responsible doctor or the manufacturer of the
medical equipment.
We also advise you to keep a minimum distance of 50cm
between the GSM antenna of the iThink module and any
medical equipment (pacemaker, hearing aids, etc.).
The radio transmitter contained in the GSM of the iThink
module may interfere with the navigation system and / or
aircraft communication. You should not connect the GSM
from the iThink module inside aircraft.
You should not use GSM from the iThink module in explosive
atmosphere environments.
Never open the DIN rail support box.
The opening of this
may imply the loss of warranty.
5.
CONNECTIONS:
Conductors Cross Section:
Circuit Power Supply:
Cable CAT 6 UTP;
The use of a low cross section cable causes voltage
drops that could lead the module into protection mode
caused insufficient supply voltage.
Never connect feeders with output other than 12V 5A.
MDiBus Connections:
To connect the MDiBus, use CAT 6 UTP cable with RJ45
connectors according to EIA568A or EIA568B standards. This
connection is made to the first Mordomus module.
In MDiBus there should be no branches.
Connections Table:
Nr
Function
Nr
Function
1
GND
10
+ 12VDC
2
Digital IN Ch1/Meter
11
Output OC 1
3
Digital IN Ch2/Meter
12
Output OC 2
4
Digital IN Ch3
13
Output OC 3
5
Digital IN Ch4
14
Output OC 4
6
Digital IN Ch5
15
Output OC 5
7
Digital IN Ch6
16
Output OC 6
8
Digital IN Ch7
17
Output OC 7
9
Digital IN Ch8
18
Output OC 8
Manual: iThink-1827-EN
Pág.
1
/
2