background image

The appliance's gas inlet fitting is a 1/2« male threaded conic 
gas type in accordance with the ISO 7-1 standards. Make the 
connection using rigid pipe.

When making the gas connection, it is important to place the 
gasket (A) in between the inlet pipe (C) and the elbow (B), 
toensure a gas tight seal.

B

A

C

This appliance must be connected by a competent person, using 
fixed wiring via a double pole switched fused spur outlet with a 
fuse rating of 3amps, and with a contact separation of at least 
3mm in all poles.

We recommend that the appliance is connected by a qualified 
electrician who will comply with I.E.E  regulations.

The wires in the mains lead are coloured in accordance with the 
following code: Green & Yellow = Earth, Blue = Neutral, Brown = 
Live

GAS CONNECTION

ELECTRICAL 

CONNECTION

CONNECTION DIAGRAM
Caution! Voltage of heating elements 220 V
Caution! In the event of any connection the safety wire 

must be connected to the  

 

 PE terminal.

Recommended 

type of 

connection

 

N

 

 

 

L

For 220 V earthed one-phase connection, bridges connect 

L terminals and N terminals, safety PE wire to  

 

 

 

N

PE

L

8

Содержание VDP645GB3

Страница 1: ...tructions thoroughly to make sure that you have not missed anything WARNING For your own safety make sure that these instructions on Installation use and maintenance are followed We advise you to keep...

Страница 2: ...M PLASTIC STAINLESS STEEL Cleaning Safety instructions Ensure that these notes and that the whole of this instruction book are thoroughly read and understood before installation or operation of the ho...

Страница 3: ...o not cover the hob or place combustible materials on or near the surface even when the hob is not in use 10 Do not fill deep fat frying pans more than one third full of oil Do not leave unattended 11...

Страница 4: ...also require a permanent vent If the room has a volume between 5 and 10 m3 it will require an air vent of 50 cm2 effective area unless it has a door which opens directly to If the room has a volume of...

Страница 5: ...Fix in position in fig 4 If fitting a 600 mm bridging unit above the 700 mm hob unit the sides of adjacent cabinets may be lower than 760 mm down to 334 mm provided they are resistant to heat and stea...

Страница 6: ...x this gasket evenly without gaps or overlapping to prevent liquids from seeping underneath the hob 1 Remove the pan stands and the burner caps then turn the hob upside down taking care not to damage...

Страница 7: ...f 3amps and with a contact separation of at least 3mm in all poles We recommend that the appliance is connected by a qualified electrician who will comply with I E E regulations The wires in the mains...

Страница 8: ...C and turn the bypass screw left or right until flame of the burner is conveniently regulated to the low position Make sure that when turning quickly from Full on position to reduced rate position tha...

Страница 9: ...ed to light the burners in the event of a power failure Keep the control knob pressed in for 15 seconds ensuring the burner stays lit when released If the burner fails to stay lit wait for 1 minute be...

Страница 10: ...a problem with your hob UNEVEN OR YELLOW FLAME RATHER THAN BLUE Switch off and check the following points 1 Are the burners fitted correctly 2 Are the holes in the burner clear 3 Check that no dust ha...

Страница 11: ...ioxide the exhaust of combustion products is affecting our environment when reach a certain amount of CO and CO2 To ensure the rational use of energy please install the gas hob according to the specif...

Страница 12: ...e must be installed in compliance with the current provisions in force and only used in rooms equipped with adequate ventilation Consult the instruction manual before proceeding with installation or u...