Mora MMIX Clinic

DANSK

Vi anbefaler, at du benytter en uddannet VVS-installatør. 
OBS! Ved nye rørinstallationer skal ledningerne frem til blandingsbatterierne  
spules rene, inden blandingsbatteriet monteres.
 

FEJLSØGNING/SERVICE

A

 

Dårlig stråle:

A:1

 Afmontér strålesamleren (a), og rengør den.  

A:2

 Hvis det ikke hjælper, så rengør filtrene i indløbsniplerne (b): Luk først af for det 

indkommende vand. Afmontér blandingsbatteriet fra vægpladen: Hold niplen fast med en 
skiftenøgle [1], så den ikke roterer, og skru samtidig møtrikkerne med en anden skiftenøgle 
[2] ved at dreje med uret. Rengør filtrene.

A:3

 Hvis der stadig er et dårligt flow, udskift termostatindsatsen (c): Skru med en unbra-

konøgle (4 mm) skruen ud [1], og løsgør drejegrebet [2]. Fjern skoldningsbeskyttelses-
ringen [3]. Skru overdelen løs [4] iht. følgende: Tryk spindlen [5] ind, og hold den fast, så 
den ikke roterer med rundt, samtidig med at møtrikken [6] skrues på med Mora Armaturs 
serviceværktøj (Art.nr. 891096). Træk termostatindsatsen ud [7], og monter den nye i 
omvendt rækkefølge.

Lækage fra badekartud/bruser, når blandingsbatteriet er lukket

Udskift overstykket: Luk først for vandtilgangen. Skru dækslet løs [1] med en lille skrue-
trækker. Skru skruen ud [2], og løsgør greb og dækring [3]. Udskift overstykket [4]. Skru 
overstykket løs ved hjælp af en skiftenøgle.
 

Giver kun koldt eller varmt vand. Blandingsbatteriet reagerer ikke ved temperatur-

regulering:

 Blandingsbatteriet er fejltilkoblet. Luk først af for det indkommende vand. Det 

varme vand skal kobles til blandingsbatteriets venstre side (ved mængderegulering).

C

 

Kalibrering af temperatur

Kalibrér blandi ngsbatteriet: Afmontér temperaturgrebet [1] som vist [

A:3

 1-3]. Drej spind-

len (b) tills en komfortable temperatur er indstillet. Monter skoldningsbeskyttelsesringens 
(a) stopkonsol 

1

, så den kommer på niveau med markeringen 

2

 på blandingsbatteriets hus.

D

 Spuling med varmt vand

Stik en 2,5 mm inhexskruetrækker (g) ind i drejegrebet, og skru varmtvandsspærren udad 
(mod uret), til stop. Bruseren skal kunne tåle spuling med varmt vand, for eksempel Mora 
Safe bruserslange og håndbruser.
Åbn volumengrebet, og ublandet varmt vand spules nu gennem blandingsbatteriet. Spul 
med lavt flow.
Efter gennemspuling genindstilles blandingsbatteriet!
Skrue varmtvandsspærren indad (med uret) til stopstilling. Efter stopstilling kan man skrue 
mere op, men grebet går da meget stramt. Blandingsbatteriet er nu stillet helt tilbage til 
den tidligere indstilling med fungerende skoldningsbeskyttelse og varmtvandsspærre.

Skoldningsrisiko ved varmtvandsspuling!

Mora Armatur tager gerne gamle armaturer retur til genanvendelse.

ENGLISH

Installation should be carried out by a professional water and sanitation expert.
NB: When installing new pipes, the pipes leading to the mixer must be thoroughly flushed 
clean before the mixer is mounted.
 

TROUBLESHOOTING/SERVICE

B

 

The mixer emits too little water: 

A:1

  Dismantle the aerator (a) and clean it. 

A:2

 If this does not help, clean the filters in the inlet nipples (b): First turn off the incoming 

water. Dismantle the mixer from the wall fixture: Hold it in place with a spanner [1] to 
prevent the nipple from rotating, while turning the nut clockwise with another spanner [2]. 
Clean the filters. 

A:3

 If the flow rate is still poor, replace the thermostat cartridge (c): Remove the screw [1] 

with a 4 mm Allen key and lift off the knob [2]. Remove the scalding protection ring [3]. 
Unscrew the top piece [4] as follows: Push in the spindle [5] and hold it securely so that 
it cannot rotate while unscrewing the nut [6] using the Mora Armatur service tool (Art. no. 
891096). Remove the thermostat cartridge [7] and fit the new one in the reverse order.

B

 

Dripping from bath spout/shower when mixer is turned off

Replace the head piece: First turn off the water supply. Unscrew the cover [1] with a small 
screwdriver. Remove the screw [2] and remove the lever and cover ring [3]. Replace the 
head piece [4]. Use an adjustable spanner to unscrew the head piece.

The mixer only emits cold or hot water. The temperature does not change when the 

temperature control knob is turned:

The mixer is incorrectly connected. First turn off the incoming water. The hot water should 
be connected on the left-hand side of the mixer (for flow control).

C

 

Calibration of temperature

Calibrate the mixer: Dismantle the flow control knob [1] according to the instructions in 
[

A:3

 1-3]. Turn the spindle (b) until the desired temperature is set. Mount the stop lug 

1

 for 

the scalding protection ring (a) so that it aligns with the mark 

2

 on the mixer body. 

D

 Flushing with hot water

Insert a 2.5 mm Allen key (g) into the knob and unscrew the hot water lock (anti-clockwise) 
until it stops. The shower set must be capable of withstanding hot water, e.g. a Mora Safe 
shower hose and hand shower.
Open the flow control knob. Unmixed hot water will flush through the mixer. Flush at a low 
speed.
After flushing with water, reset the mixer.
Screw the hot water lock inwards (clockwise) until it stops. It can be turned beyond the 
stop position, but it will be very stiff. The mixer has now been completely reset to its previ-
ous setting, and the scald protection and hot water lock are fully functional.

Warning: Risk of scalding when flushing with hot water.

 

Disused products can be returned to Mora Armatur for recycling.