4. Reinstall the IPM
Retaining Clips
a. Reinstall the IPM on the
IPM mounting bracket by
engaging the (3) retaining clips.
d. Reinstall the “Secondary Lock” into the front of the
connector.
e. Reinstall the “B” connector back into the IPM.
Violet/Lt. Blue Wire
c. Insert the Violet/Lt. Blue wire from the hood switch
harness into the “B” connector, location 10
(G70 Circuit).
Note: Refer to picture for proper terminal
orientation.
8 of 12