Manual Part No: 932975-01
MD Gas Grill
Page 11 of 31
Manual Rev No: 1
Installation (cont.)
Positioning (cont.)
Adequate ventilation is essential for safe operation of a gas appliance. A supply of fresh air is necessary
for the correct combustion of the gas and there must be a means of exhausting the heat and the
products of combustion from the kitchen. It is recommended that the appliance be sited
below a
ventilating hood, one preferably connected to an extractor system incorporating a grease filter.
These appliances are to be installed with sufficient ventilation to prevent the occurrence of unacceptable
concentrations of substances harmful to health in the room in which they are installed.
If the grill is to be positioned in such a way that it is possible to touch the rear of the grill when hot, then
a Heat Shield (available as an accessory)
MUST
be fitted to the back panel.
Accessory Kit: - CL6G-HS Heat Shield Kit (600 Grill)
CL9G-HS Heat Shield Kit (900 Grill)
Important Note
The appliance
MUST NOT
be connected
DIRECTLY
to a flue or ventilating system, although the flue
products of two or more appliances may be directed into a common outlet when building a suite of
appliances (see separate instructions for suiting appliances).
Ensure that the appliance is level in two places - front to rear and side to side. To check the level it is
recommended that a spirit level be placed on the toast rack.
Gas Connection
Natural Gas: The size of the supply pipe should be no smaller than 3/8” BSP and an easily accessible
stopcock must be fitted in the gas line adjacent to the appliance. The gas governor provided with the
appliance MUST be fitted in the supply line
BETWEEN
the stopcock and the appliance.
Although a rigid gas pipe is recommended, armoured flexible pipe of a
GAS COUNCIL APPROVED
PATTERN
may be used.
Ensure that all the pipes to the appliance are clean and free from swarf etc,
BEFORE
making the final
connection.
Propane Gas: Follow the same procedure as that for Natural Gas
EXCEPT
that the Gas Governor
MUST
NOT
be fitted - the Gas Supply Tank or Cylinders are already fitted with a Gas Regulator.