background image

4

TRUNKGUARD™

 Fieldbus Power Conditioner

FPS200

Figure 2.

 Hook-Up Diagrams for Simplex and Duplex Configurations

Figure 1.

 FPS201 Dimensions

FPS201-4 (-S)

FPS201-8

FPS201-2

239mm  

(9.41 in)

SURGE GROUND
CONNECTION

MOORE INDUSTRIES-INT'L., INC.  U.S.A.

12

ALARM

DC POWER

S

S

1

2

ALARM

DC POWER

DCS CONNECTION 

A

DCS CONNECTION B

SURGE GROUND
CONNECTION

S

S

S

S

T

1

2

3

4

FIELD

 1

FIELD

 2

FIELD

 3

FIELD

 4

S

S

S

S

T

T

T

FIELD

 1

FIELD

 2

S

S

T

1

2

T

125mm  

(4.92 in)

125mm  

(4.92 in)

115mm 

(4.53 in)

FRONT VIEW

FRONT VIEW

SIDE VIEW

MOORE INDUSTRIES-INT'L., INC.  U.S.A.

Alarm

Contacts

 

(Volt -free) 

DC Power

Field Segment

DCS Segment

Simplex
Example

Duplex
Example

DCS multi-core cable
(where applicable)

Alarm

Contacts

(Volt-free)  

DC Power

DCS Segment

Field Segment

Surge

Ground

Connection

Note: 

If only one DC power feed is to be used, a pair of 
jumper wires is required to the second set of DC
feed terminals to ensure that the alarm monitoring
circuit operates correctly.

Содержание Trunkguard FPS200

Страница 1: ...FPS200 FPS200 April 2016 920086B TRUNKGUARD FieldbusPowerConditioner TRUNKGUARD Fieldbus Power Conditioner...

Страница 2: ...troduction 3 Installation 3 Wiring Connections 3 Dimensions 4 Wiring Layout 4 Terminator 5 Testing and Troubleshooting 5 Recommended Ground Wiring Practices 6 CE Conformity 6 Operation 6 Maintenance 6...

Страница 3: ...ned to fit onto a 32mm EN50035 G type and 35mm EN50022 Top Hat DIN rail and should be mounted in such a way as to allow easy ac cess to terminal receptacles and to keep LEDs visible Horizontal DIN rai...

Страница 4: ...ELD 2 FIELD 3 FIELD 4 S S S S T T T FIELD 1 FIELD 2 S S T 1 2 T 125mm 4 92 in 125mm 4 92 in 115mm 4 53 in FRONT VIEW FRONT VIEW SIDE VIEW MOORE INDUSTRIES INT L INC U S A Alarm Contacts Volt free DC P...

Страница 5: ...s usually re quired at the Carrier with the other terminator on the segment provided by the Device Coupler In this con figuration there should not be a terminator in the cir cuit at the DCS Contact Mo...

Страница 6: ...etic Compat ibility directives 89 336 EEC EN 61326 Consult the factory for the most current information on products that have been CE certified Operation During normal operation the GREEN LED should b...

Страница 7: ...CH OF ANY WARRANTY CONCERNING THE GOODS OR SERVICES SHALL BE FOR THE COMPANY AT ITS OPTION TO REPAIR OR REPLACE THE GOODS OR SERVICES OR REFUND THE PURCHASE PRICE THE COMPANY SHALL IN NO EVENT BE LIAB...

Отзывы: