Selection 

Switches

Many operational 

parameters of the 

SRAC2 can be set or 

changed by position 

switches - either by 

a single switch or a 

combination of ON/OFF 

settings of 2 or more 

switches.

 

SW1 

SW2 

SW3 

SW4 

SW5 

SW6 

SW7 

SW8 

Running Current

           

Microstepping

 

 

SW9 

SW10

 

SW11

 

SW12 

Idle Current

Anti Resonance

Step Input Signal Filter

Self Test

Smoothing Filter

Microstepping - 4 switches for a total of 16 settings:

Microstep(step/rev)

SW1

SW2

SW3

SW4

200

ON

ON

ON

ON

400

OFF

ON

ON

ON

800

ON

OFF

ON

ON

1600

OFF

OFF

ON

ON

3200

ON

ON

OFF

ON

6400

OFF

ON

OFF

ON

12800

ON

OFF

OFF

ON

25600

OFF

OFF

OFF

ON

1000

ON

ON

ON

OFF

2000

OFF

ON

ON

OFF

4000

ON

OFF

ON

OFF

5000

OFF

OFF

ON

OFF

8000

ON

ON

OFF

OFF

10000

OFF

ON

OFF

OFF

20000

ON

OFF

OFF

OFF

25000

OFF

OFF

OFF

OFF

Idle Current(

SW8)

  - 1 switches for a total of 

2settings:

Idle

SW8

50%

ON

90%

OFF

Step Input Signal Filter (

SW9

) - ON for 150 kHz, OFF 

for 2 MHz

Running current - 3 switches for a total of 8 settings:

Current(Peak)

SW5

SW6

SW7

0.6A

ON

ON

ON

0.8A

OFF

ON

ON

1.0A

ON

OFF

ON

1.2A

OFF

OFF

ON

1.6A

ON

ON

OFF

1.8A

OFF

ON

OFF

2.0A

ON

OFF

OFF

2.5A

OFF

OFF

OFF

Anti-Resonance(

SW10

)  - 1 switches for a total of 2 

settings:

Option

SW10

Inertia

0

ON

Low

High

1

OFF

Step Smoothing Filter (

SW11

) - ON to enable, OFF to 

disable
Self test (

SW12

) - ON for 1 rev CW/CCW 0.5 rps self 

test, OFF for none