Moonlight High Resolution Stepper Motor Скачать руководство пользователя страница 7

and the focus controller.  Windows will state that it has found new hardware and needs to install drivers.  When 
prompted, select “Have Disk” and select the directory where the files were unzipped.  The installer should then 
complete the software installation.

Please make sure you have downloaded and installed the latest version of ASCOM 

http://ascom-standards.org/

   

Please download our most current ASCOM driver from our website.  Installation documentation and the drivers 
are located here   http://www.focuser.com/downloads.shtml   Please see our tutorial for setting up the focuser to 
run with Focus Max  at 

http://www.focuser.com/cgi-bin/dman.cgi?page=fmflw

 

Generic serial commands can be used to operate the controllers if needed. Please see table below for

command set.

Serial Commands

Command

 

Return

Comments

Char #

 

Variable

 

1

2

3

4

5

6

7

8

 

 

 

:

C

#

 

 

 

 

 

 

N/A

Initiate a temperature conversion; the conversion

process takes a maximum of 750 milliseconds. The

value returned by the :GT# command will not be

valid until the conversion process completes.

:

F

G

#

 

 

 

 

 

N/A

Go to the new position as set by the ":SNYYYY#"

command.

:

F

Q

#

 

 

 

 

 

N/A

Immediately stop any focus motor movement.

:

G

C

#

 

 

 

 

 

XX#

Returns the temperature coefficient where XX is a

two-digit signed (2’s complement) hex number.

:

G

D

#

 

 

 

 

 

XX#

Returns the current stepping delay where XX is a

two-digit unsigned hex number. See the :SD#

command for a list of possible return values.

:

G

H

#

 

 

 

 

 

00# OR FF#

Returns "FF#" if the focus motor is half-stepped

otherwise return "00#"

:

G

I

#

 

 

 

 

 

00# OR 01#

Returns "00#" if the focus motor is not moving,

otherwise return "01#"

:

G

N

#

 

 

 

 

 

YYYY#

Returns the new position previously set by a

":SNYYYY" command where YYYY is a four-digit

unsigned hex number.

:

G

P

#

 

 

 

 

 

YYYY#

Returns the current position where YYYY is a

four-digit unsigned hex number.

:

G

T

#

 

 

 

 

 

YYYY#

Returns the current temperature where YYYY is a

four-digit signed (2’s complement) hex number.

:

G

V

#

 

 

 

 

 

DD#

Get the version of the firmware as a two-digit

decimal number where the first digit is the major

version number, and the second digit is the minor

version number.

:

S

C

X

X

#

 

 

 

N/A

Set the new temperature coefficient where XX is a

two-digit, signed (2’s complement) hex number.

:

S

D

X

X

#

 

 

 

N/A

Set the new stepping delay where XX is a two-digit,

unsigned hex number. Valid values to send are 02,

04, 08, 10 and 20, which correspond to a stepping

delay of 250, 125, 63, 32 and 16 steps per second

respectively.

:

S

F

#

 

 

 

 

 

N/A

Set full-step mode.

:

S

H

#

 

 

 

 

 

N/A

Set half-step mode.

:

S

N

Y

Y

Y

Y

#

 

N/A

Set the new position where YYYY is a four-digit

Содержание High Resolution Stepper Motor

Страница 1: ...of the focuser turn the silver knurled ring loose For motor operation of the focuser tighten the silver knurled ring To adjust the knurled rings tension it helps to hold the manual knob still with yo...

Страница 2: ...emote temp probe can be plugged into the controller to bypass the built in temp probe located inside the case Once plugged in it will defeat the internal temp sensor The probe can be taped to the side...

Страница 3: ...f the above settings to the factory defaults Activate by pressing both Blue Buttons at the same time DONE Exits the setup menu and saves all settings to EEPROM If a mistake was made simply cycle power...

Страница 4: ...etained motor is stopped Example To set a new position SN0537 For motor 2 all of the above commands are available just precede the command with a 2 Motor 2 Example To set Motor 2 to a new position 2SN...

Страница 5: ...itions that are frequently used Just go to the step count you want and then click Store and the SP button you want to assign the step count value to Once finished with storing all 5 button values clic...

Страница 6: ...screen shot of Focus Max Computer Connection Operation Connect the controller to your PC using USB Windows should show new hardware found and install the devise automatically If your laptop is older y...

Страница 7: ...ovement G C XX Returns the temperature coefficient where XX is a two digit signed 2 s complement hex number G D XX Returns the current stepping delay where XX is a two digit unsigned hex number See th...

Страница 8: ...s will release idle current to the motor windings when not moving to reduce current consumption and also reduce heat generated by the motor itself however some controllers like ROBO focuser and others...

Страница 9: ...tip tilt ability of the focuser s flange will come in handy Please Note rotating the focuser will throw off any collimation reference once the flange is tilted off plane So please do not collimate the...

Страница 10: ...he slip clutch is is not tight enough on the motor tighten clutch as shown in motor documentation If the manual knob on the right is moving but the drawtube is not moving then the drawtube is slipping...

Страница 11: ...MoonLite Telescope Accessories 755 Preserve Road Danville PA 17821 570 437 2232 www focuser com Rev 09 13...

Отзывы: