Image 7.43: Test signal generator for square signal
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
162
7 Control
ID
Parameter /
Setting
Function
Info
1500
SCD_TSIG_
Con
Control word of test signal
generator
The parameter is reset to the
value 0 on completion of the
stop procedure.
OFF (0)
Test signal generator
deactivated
Stop(1)
Stop test signal
Start(2)
Start test signal
STOP-Cycle(3)
TG stops at end of current
square cycle
Stop-Zero(4)
TG stops next time
reference value passes
through zero
1501
SCD_TSIG_
OutSel
Test signal generator
output selector
OFF (0)
Not used
isdref(1)
Flux-forming current
mref(2)
Torque
sref(3)
Speed
epsref(4)
Position
sramp(5)
Speed (ramp)
ISQREF(6)
q-current reference
ISDQREF(7)
d-current q-current
reference
Table 7.38: Parameters of test signal generator for square and sine signal