22
Mechanical installation
A1
A
H
T
D1
B
Figure 2.13 Dimensional drawing, step-up choke, example for size 5 and size 6A
NOTE:
The step-up choke is a primary heat source, and should be treated as a
hotspot component. This component is cooled by natural air convection
(gravity circulation). In order to make effective use of this physical effect, this
component should be installed in the lower plinth area of the switch cabinet
on stable mounting rails (permitting unhindered air flow from below). When
selecting the position, air inlet at the filter mat or – better still – at the input
fan zone is advisable.
2.6
Step-up choke installation
Arrange the components and cables at a distance of >100 mm (3.94 in) from the step-up choke,
so as to minimise influencing of the adjacent components by magnetic leakage flux and ensure
adequate air circulation for cooling. Position the step-up choke as close as possible to the Power
Supply Unit.
Mark out the position of the tapped holes on the mounting rail.
Cut a tap for each fixing screw in the backing plate.
Take into account the bend radius of the connecting cables.
Dimensional drawings/hole spacing see Figure 2.13 and Table 2.3.
Mount the step-up choke on the mounting rail.
The tapping area will provide you with good, full-area contact. The contact area must be
metallically bright, in order to make a good earth connection to the cabinet earth.
2.6.1
Dimensions
For size
Size 5
Size 6A
For model
G396-026
G396-050
G396-075
G396-110
B (width)
239 (9.41)
299 (11.77)
335 (13.19)
380 (14.96)
H (height)
273 (10.79)
300 (11.81)
344 (13.54)
399 (15.71)
T (depth)
124 (4.88)
135 (5.31)
158 (6.22)
200 (7.87)
A
185 (7.28)
210 (8.27)
248 (9.76)
280 (11.02)
A1
75 (2.95)
95 (3.74)
122 (4.80)
127 (5.0)
D1
10 x Ø 18 (0.71) 12 x Ø 20 (0.79)
12 x Ø 20 (0.79)
12 x Ø 20 (0.79)
Fixing screws
4 x M8
4 x M10
4 x M10
4 x M10
Weight
16 kg (35.27 lb) 27 kg (59.52 lb) 37.5 kg (82.67 lb) 56 kg (123.46 lb)
All dimensions in mm (in) and excluding terminals/connectors
Table 2.3 Step-up choke dimensions