Programmable Multi-Axis Servo Drive Power Supply Unit Operation Manual
ID no.: CA97556-001 Date: 03/2015
moog
19
Mechanical installation
Multi-Axis Servo Drive size
4
Power Supply
Unit size 5
Multi-Axis Servo Drive size
3
Multi-Axis Servo Drive size
2
Multi-Axis Servo Drive size
1
Figure 2.8 Butt-mounting, axis array, liquid-cooled, Power Supply Unit size 5
Multi-Axis Servo Drive size
4
Multi-Axis Servo Drive
size 6A
liquid-cooled
Multi-Axis Servo Drive size
3
Multi-Axis Servo Drive size
1
Power Supply Unit
size 6A
liquid-cooled
Multi-Axis Servo Drive size
5
Multi-Axis Servo Drive size
2
18.5 mm (0.73 in)
Figure 2.9 Butt-mounting, axis array, liquid-cooled, Power Supply Unit size 6A
2.4
Power Supply Unit installation
Liquid-cooled housing
Arrange the devices starting from the Power Supply Unit to the right or left sorted in descending
order of power output, in order to exclude thermal influences. Before installing the devices and
components in the cabinet refer to the instructions relating to EMC installation.
Align Power Supply Unit
size 5
and all Multi-Axis Servo Drives in a line along the top edge of
the unit (see dotted line in Figure 2.8). This is necessary in order to execute the DC power supply
using the ready made-up cables.
Align all Multi-Axis Servo Drives in a line along the top edge of the unit. Align Power Supply Unit
size 6A
offset 18.5 mm (0.73 in) down (see Figure 2.9). This is necessary in order to execute
the DC power supply using the ready made-up cables.
Mark out the positions of the tapped holes and the pipe socket on the backing plate.
Drill holes and cut a thread for each fixing screw in the backing plate.
Pay attention to the installation clearances. Also take into account the bend radius of the
connecting cables. Dimensional drawings/hole spacing see Figure 2.8 to Figure 2.10 and
Mount the Power Supply Unit vertically and abutting on the backing plate.
The contact area must be metallically bright. For the DC power supply use the supplied ready
made-up cables.
When fitting the hose connections (not supplied) in the pipe sockets, brace with a 22 mm
(0.87 in) open-ended wrench in order to prevent damage to the device by torsion.
Ensure a perfect liquid-tight connection (e.g. using a Teflon sealing strip).
For more information on liquid cooling refer to section A.4, p. 70.
The next stage is installation of the mains connection set.
1.
2.
3.
4.