MRJ06301
Range H
Range H
changes the value of all profile points by a
percentage of the difference between the thickness
and thinnest points. The value of the thinnest profile
point remains constant during a Range H change.
Range H can vary between
–100% and non limit + side
(3276.7%).
* If the profile over 100%,
Range H
still can be increase
continuously, however actual profile command is 100%
maximum.
Use the
Rotaly Knob
and
SET
to change the
Range
H
setting. The percentage
Range
H
change will remain
displayed after being
Set
. When the
Rotaly Knob
is
turned again the new
Range H
entry will start at zero
using the current display as a reference. If the
Rotaly
Knob
is accidentally moved and the displayed
Range
H
value changed, it will revert to its former value if
SET
is not pressed and the
Cursor
used.
Figure 2-14 0% Range H
Range H
has the effect of allowing container weight
changes while retaining the containers minimum wall
thickness distribution pattern.
Figure 2-15 shows the effect of a
Range H
increase of
+25.0% from the
Range H
value of 0% in Figure 2-14.
To make the change easier to visualize, reference lines
drawn between the figures starting at four different par-
ison wall thickness program points have been included.
Range H
will use the thinnest parison wall thickness
program point as a reference and will not change its
thickness. The
Range H
change will be largest at the
maximum parison wall thickness point, and proportion-
ately less at the intermediate parison wall thickness
poins.
Figure 2-15 (+)25.0% Range H Change
The lowest
thickness will
be fix