Moog ACV with CANopen bus interface
7 Servo valve functions
Flow control
B99224-DV018-D-211, Rev. A, October 2018
219
7.12.4 Sample frequency
The sample frequency is equal to the <BasicSampleFrequency> (0x3030).
Chapter "7.1.13.1 Object 0x3030: Basic sample frequency", page 136
7.12.5 Flow control mode
The <FlwControlMode> (0x5205) is used to select the connection variants of the existing pressure sensors.
Figure 131: Flow control mode
Edge for y>0
Edge for y<0
Pressure sensor at
cylinder connector A
Pressure sensor at
cylinder connector B
Flow control mode
<FlwControlMode>
(0x5205)
P-A
P-B
x
x
0
P-A
A-T
x
1
B-t
P-B
x
Not implemented
P-A (y>0)
p
A
u
p
B
u
p
P
u
p
T
u
A-T (y<0)
p
A
u
p
B
u
p
P
u
p
T
u
x
x
B-T (y>0)
p
A
u
p
B
u
p
P
u
p
T
u
P-B (y<0)
p
A
u
p
B
u
p
P
u
p
T
u
x
x
Bernoulli
compensation
Bernoulli
compensation
Bernoulli
compensation
Bernoulli
compensation