Moog Videolarm QMRC Series Скачать руководство пользователя страница 10

- 11 -

AC Voltmeter

Camera

Monitor

Bridge Tap

NV-213

A

NV-213

A

NVT TROUBLESHOOTING

If you are experiencing problems, attempt to simplify your setup. Test 
each  cable  segment  separately.  For  example,  test  the  camera  and 
monitor together without the other equipment. Then add in the NVT 
transceivers,  back-to-back.  Test  each  segment  of  a  long  cable-run 
independently. Attempt to isolate the problem.
Below are problems that may be encountered. If the suggestions below 
are not helpful, or the recommendations are not effective, please call 
NVT’s customer support. NVT customer support can be reached 8:00 
AM to 5:30 PM PST at (800) 959-9870 or at (+1) (650) 562-0600.

FAINT OR BLURRY PICTURE; LITTLE OR NO COLOR

Possible causes include:
1.  Shielded  twisted-pair  cable.  Verify  that  the  wire  is  unshielded 

twisted-pair cable. Multi-pair cable with an overall shield is OK.

2. Longer wire distance than expected. Be sure to include any coax 

cable  that’s  part  of  this  distance.  Verify  end-to-end  connectivity 
with  an  ohm  meter.  Measure  the  distance  by  disconnecting  the 
transceivers,  shorting  the  far  end,  reading  the  loop’s  resistance 
at  the  near  end.  See  above  for  ohm  vs.  distance  ratings.  If 
necessary, replace transceivers with correct models specified for 
this distance.

3. Incorrect  distance  equalization  setting.  Adjust  the  equalization 

controls) with a mini screwdriver (NV-652R, NV-862R or the NV-
1662R). If the transmitter is an NV-653T, verify correct equalization 
switch setting.

4. Poor connection at a punch-block, splice, or coax cable. Re-check 

using the method described in #2 above, or use a wire test set.

5. Short between conductors of the twisted-pair. Use an ohm meter to 

locate the short.

6. Transient protection devices employing metal-oxide varistors. Use 

carbon blocks, gas-discharge tubes, or NVT transceivers w

i

th built-

in protection.

7. Check the camera. Are the focus and iris set correctly? Verify with 

portable monitor.

EXTREMELY FAINT PICTURE

 

Only  faint  shadows  of  the  original  picture  are  visible.  One  of  the 
twisted  pair  conductors  is  open  or  the  wires  are  shorted  together. 
Check with an ohm meter.

OVER-SATURATED COLORS; HIGH CONTRAST GRAINY 

PICTURE; TOO BRIGHT, TORN PICTURE

Adjust the distance equalization as necessary. Verify that the monitor 
has a 75 termination, not in “loop-through”.

WON'T SYNC; WIDE, WHITE JAGGED AREAS

Looks like a scrambled Cable TV signal. Check polarity.

WON'T SYNC; TORN PICTURE

1. Make sure that you are using unshielded twisted pair wire. 
2. Check distance equalization settings. 
3. For  installations  with  passive  (non-amplified)  transceivers  at  both 

ends,  check  for  ground  loops.  This  may  be  done  with  an  AC 
Voltmeter, as shown below:

  If  the  voltage  is  greater  than  1/2  volt,  use  an  amplified  receiver, 

such as the NV-652R, NV-862R, or NV-1662R.

  Alternately, remove the ground at one end (usually at the camera 

end). Be sure that floating the camera conforms to local/regional 
and National Electrical Codes. 

4. Check for crosstalk from a second video path. Disconnect all other 

video sources. If the problem goes away, check for a split-pair or 
un-twisted wire.

FAINT STRIPES GLIDING UP OR DOWN THE SCREEN

These  are  caused  by  crosstalk  from  a  second  video  path,  or  with 
ground-loops in installations employing passive models at both ends. 
1. To  identify,  disconnect  all  other  video  signals  temporarily.  If  the 

interference goes away, check the wire to make sure the signal is 
traveling through a twisted pair. Is two-way video being sent more 
than  1,000  ft  (300m)  over  Category  2  or  3  wire?  If  so,  the  send 
and receive signals may need to go in separate jacketed cables, 
or upgrade to Category 5 wire.

2. Next, check for ground loops. See #3 above.

NO POWER LIGHT ON THE NVT UNIT

Check the blue “power” LED on powered NVT units. If the light is not 
on, the receiver is not getting power. Re-check the power source and 
connections. 
If the green LED is on but the power LED is off, check that the power 
supply is floating. Grounding one side of the power input may cause 
this condition.

NO GREEN LIGHT, NO VIDEO

The  NV-652R,  NV-862R  or  NV-1662R  series  receiver/hub  is  not 
detecting a video signal. There is an open or shorted connection. Use 
a multimeter to locate the fault. 

GHOSTS

Faint  shadows  of  the  original  signal  shifted  to  the  right.  This  is 
caused  by  an  impedance  mismatch  along  the  wire.  Verify  that  the 
monitor is terminated with 75 (not in “loop-through”.) Check that all 
wire is 

unshielded

 twisted pair. The high-frequency wire impedance 

should be 100. Check for bridge-taps (see below) either by inspecting 
wiring  closet  connections,  or,  if  available,  using  a  “Time-Domain 
Reflectometer” (T.D.R.), sometimes called a “cable tester”.
If the faint shadows are not copies of the original picture, but from the 
picture of some other camera, check for crosstalk:
Is any portion of the wire un-twisted?
Are the signals from two cameras split between two pairs?
Is there a short between a conductor of one signal and a conductor 
of another?

Содержание QMRC Series

Страница 1: ...EVISION DATE July 6 2004 81 IN5258 07064 QMR Ceiling Mount Dome QMR T C X XXXX Figure 1 Figure 2 7 With the bottom flange pressed up against the ceiling rotate the support arms to the outside the arms will fall to the back side of the ceiling Tighten the 3 support arm screws Figure 2 8 If the housing is going into a ceiling where the support arms will not work secure the housing by running bolts in...

Страница 2: ...IVE For refer ence purposes Polarity is not important in this unit The GREEN wire labeled Ground is GROUND for VAC or VDC connections NOTE Connect green ground wire to earth ground metal conduit metal stud etc 2 Attach the BNC connectors to the video in Auto Iris Lens NOTE THE AUTO IRIS LENS IS SET AT THE FACTORY IF YOU EXPERIENCE VIDEO TOO LIGHT OR DARK AUTO IRIS ADJUSTMENT MAY BE NEEDED SEE THE ...

Страница 3: ...is in the on position the auto iris lens controls the amount of light on the chip If in the off position the light level is controlled electronically Used to help improve the color quality of the camera picture under different light ing conditions The Fac tory Default is Switch 7 ON switches 6 and 8 OFF NOTE ANY ADJUSTMENTS TO THESE SETTINGS SHOULD ONLY BE MADE BY A QUALIFIED CCTV TECHNICIAN See e...

Страница 4: ...nnecting the receiver end of the the unshielded twisted pair cable will be included with the NVT receiver Following are instructions for connecting the unshielded twisted pair cables to the RJ45 Cat 5 cable running outside your housing UNSHIELDED TWISTED PAIR VIDEO WIRING 1 Video for all four cameras is contained in the one RJ45 Cat 5 cable An RJ45 female coupling is provided so that all connectio...

Страница 5: ...point Unshielded Twisted Pair wire gauge 24 or thicker stranded or solid Category 2 3 4 or 5 2 The video signal may co exist in the same wire bundle as other video telephone data control signals or low voltage power It is also OK to run NVT video signals in or near electromagnetic fields in accordance with National Electrical Code local or other local safety requirements 3 DO measure the wire dist...

Страница 6: ...2525 Park Central Blvd Decatur Ga 30035 770 987 7550 800 554 1124 Fax 770 987 9705 800 826 0366 www videolarm com 1 2 4 3 5 MR7 Exploded Diagram and Replacement Parts List ...

Страница 7: ...ED BRACKET 5 RPQF20NF3 HI RES B W 3 6 FIXED LENS RPQF20NA HI RES B W 4 9MM AUTO IRIS VARIFOCAL RPQF50NF3 HI RES COLOR 3 6 FIXED LENS RPQF50NA HI RES COLOR 4 9MM AUTO IRIS VARIFOCAL RPQF70NA HI RES DAY NIGHT 4 9MM AUTO IRIS VARIFOCAL N S RPQMR01 PACKET ASSEMBLY 6 RPMR7050 WHITE TRIM RING ASSEMBLY 7 RCMR7C CLEAR REPLACEMENT CAPSULE MR7 RCMR7T TINTED REPLACEMENT CAPSULE MR7 8 RPQD08 SET OF 4 SPACERS ...

Страница 8: ... charges The limited warranty stated in these product instructions is subject to all of the following terms and conditions 1 NOTIFICATION OF CLAIMS WARRANTY SERVICE If Purchaser believes that the Product is defective in material or workmanship then written notice with an explanation of the claim shall be given promptly by Purchaser to Videolarm but all claims for warranty service must be made with...

Страница 9: ...NES ON SCREEN PICTURE IS CLEAR LOW OR NO COLOR PICTURE IS DARK OR GRAINY IN GOOD LIGHTING CONDITIONS The auto iris lens is set at the factory If you experience video too light or dark you can manually adjust using the auto iris adjustment screw If there is low or no color the Auto Iris is too open if the picture is dark or grainy in good conditions the Auto Iris is too closed To adjust the auto ir...

Страница 10: ...eck polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at both ends check for ground loops This may be done with an AC Voltmeter as shown below If the voltage is greater than 1 2 volt use an amplified receiver such as the NV 652R NV 862R or NV 1662R Alternate...

Страница 11: ... LOAD POWER SUPPLY 24 AWG 22 AWG 18 AWG 16 AWG 1 2 5W 24 VAC VDC 1718 523 2733 833 6909 2106 10985 3348 2 5W 24 VAC VC 834 254 1327 404 3356 1023 5335 1626 3 7 9W 24 VAC VDC 529 161 842 256 2129 649 3385 1032 4 10 9W 24 VAC VDC 359 109 572 174 1447 441 2300 701 NOTE The above table is based on a worst case power supply Using a regulated or switching power supply can increase your cable distance Vi...

Отзывы: