NVT TROUBLESHOOTING

If you are experiencing problems, attempt to simplify your setup. Test each cable 
segment separately. For example, test the camera and monitor together without the 
other equipment. Then add in the NVT transceivers, back-to-back. Test each segment 
of a long cable-run independently. Attempt to isolate the problem.
Below are problems that may be encountered. If the suggestions below are not helpful, 
or the recommendations are not effective, please call NVT’s customer support. NVT 
customer support can be reached 8:00 AM to 5:30 PM PST at (800) 959-9870 or at 
(+1) (650) 562-0600.

FAINT OR BLURRY PICTURE; LITTLE OR NO COLOR

Possible causes include:

1.  Shielded twisted-pair cable. Verify that the wire is unshielded twisted-pair cable. 
Multi-pair cable with an overall shield is OK.

2.  Longer wire distance than expected. Be sure to include any coax cable that’s part of 
this distance. Verify end-to-end connectivity with an ohm meter. Measure the distance 
by disconnecting the transceivers, shorting the far end, reading the loop’s resistance at 
the near end. See above for ohm vs. distance ratings. If necessary, replace transceivers 
with correct models specified for this distance.

3.  Incorrect distance equalization setting. Adjust the equalization controls) with a mini 
screwdriver (NV-652R, NV-862R or the NV-1662R). If the transmitter is an NV-653T, 
verify correct equalization switch setting.

4.  Poor connection at a punch-block, splice, or coax cable. Re-check using the 
method described in #2 above, or use a wire test set.

5.  Short between conductors of the twisted-pair. Use an ohm meter to locate the short.

6.  Transient protection devices employing metal-oxide varistors. Use carbon blocks, 
gas-discharge tubes, or NVT transceivers with built-in protection.

7.  Check the camera. Are the focus and iris set correctly? Verify with portable monitor.

EXTREMELY FAINT PICTURE

 

Only faint shadows of the original picture are visible. One of the twisted pair conductors 
is open or the wires are shorted together. Check with an ohm meter.

OVER-SATURATED COLORS; HIGH CONTRAST GRAINY PICTURE; TOO BRIGHT, 

TORN PICTURE

Adjust the distance equalization as necessary. Verify that the monitor has a 75 
termination, not in “loop-through”.

WON'T SYNC; WIDE, WHITE JAGGED AREAS

Looks like a scrambled Cable TV signal. Check polarity.

WON'T SYNC; TORN PICTURE

1.  Make sure that you are using unshielded twisted pair wire. 
2.  Check distance equalization settings. 
3.  For installations with passive (non-amplified) transceivers at both ends, check for 
ground loops. This may be done with an AC Voltmeter, as shown below:

If the voltage is greater than 1/2 volt, use an amplified receiver, such as the NV-652R, 
NV-862R, or NV-1662R.
Alternately, remove the ground at one end (usually at the camera end). Be sure that 
floating the camera conforms to local/regional and National Electrical Codes. 

4.  Check for crosstalk from a second video path. Disconnect all other video sources. If 
the problem goes away, check for a split-pair or un-twisted wire.

FAINT STRIPES GLIDING UP OR DOWN THE SCREEN

These are caused by crosstalk from a second video path, or with ground-loops in 
installations employing passive models at both ends. 

1.  To identify, disconnect all other video signals temporarily. If the interference goes 
away, check the wire to make sure the signal is traveling through a twisted pair. Is 
two-way video being sent more than 1,000 ft (300m) over Category 2 or 3 wire? If so, 
the send and receive signals may need to go in separate jacketed cables, or upgrade 
to Category 5 wire.

2.  Next, check for ground loops. See #3 above.

NO POWER LIGHT ON THE NVT UNIT

Check the blue “power” LED on powered NVT units. If the light is not on, the receiver is 
not getting power. Re-check the power source and connections. 
If the green LED is on but the power LED is off, check that the power supply is floating. 
Grounding one side of the power input may cause this condition.

NO GREEN LIGHT, NO VIDEO

The NV-652R, NV-862R or NV-1662R series receiver/hub is not detecting a video 
signal. There is an open or shorted connection. Use a multimeter to locate the fault. 

GHOSTS

Faint shadows of the original signal shifted to the right. This is caused by an 
impedance mismatch along the wire. Verify that the monitor is terminated with 75 (not 
in “loop-through”.) Check that all wire is

 unshielded 

twisted pair. The high-frequency 

wire impedance should be 100. Check for bridge-taps (see below) either by inspecting 
wiring closet connections, or, if available, using a “Time-Domain Reflectometer” 
(T.D.R.), sometimes called a “cable tester”.
If the faint shadows are not copies of the original picture, but from the picture of some 
other camera, check for crosstalk:
Is any portion of the wire un-twisted?
Are the signals from two cameras split between two pairs?
Is there a short between a conductor of one signal and a conductor of another?

Содержание QMR SERIES

Страница 1: ...dome with two 2 Day Night cameras 3 9mm auto iris lens QMRT4 70NA Recessed tinted indoor outdoor ceiling dome with four 4 Day Night cameras 3 9mm auto iris lens Before attempting to connect or operate...

Страница 2: ...onents can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carto...

Страница 3: ...pect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes...

Страница 4: ...oltage must be 24 VAC VDC Figure 1 Figure 2 7 With the bottom flange pressed up against the ceiling rotate the support arms to the outside the arms will fall to the back side of the ceiling Tighten th...

Страница 5: ...IVE For reference purposes Polarity is not important in this unit The GREEN wire labeled Ground is GROUND for VAC or VDC connections NOTE Connect green ground wire to earth ground metal conduit metal...

Страница 6: ...h is in the on position the auto iris lens controls the amount of light on the chip If in the off position the light level is controlled electronically Used to help improve the color quality of the ca...

Страница 7: ...onnecting the receiver end of the unshielded twisted pair cable will be included with the NVT receiver Following are instructions for connecting the unshielded twisted pair cables to the RJ45 Cat 5 ca...

Страница 8: ...t Unshielded Twisted Pair wire gauge 24 or thicker stranded or solid Category 2 3 4 or 5 2 The video signal may co exist in the same wire bundle as other video telephone data control signals or low vo...

Страница 9: ...1 2 4 3 5 MR7 Exploded Diagram and Replacement Parts List...

Страница 10: ...d bracket 5 RPQF20NF3 hi res b w 3 6 fixed lens RPQF20NA hi res b w 4 9mm auto iris varifocal RPQF50NF3 hi res color 3 6 fixed lens RPQF50NA hi res color 4 9mm auto iris varifocal RPQF70NA hi res day...

Страница 11: ...en turning To adjust turn either clock wise or counter clockwise no more than one degree at a time Check the monitor after each turn to determine is the desired brightness and color have been obtained...

Страница 12: ...polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at both...

Страница 13: ...RAS TOTAL LOAD POWER SUPPLY 24 AWG 22 AWG 18 AWG 16 AWG 1 2 5W 24 VAC VDC 1718 523 2733 833 6909 2106 10985 3348 2 5W 24 VAC VC 834 254 1327 404 3356 1023 5335 1626 3 7 9W 24 VAC VDC 529 161 842 256 2...

Страница 14: ...ousings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via...

Отзывы: