Operating instructions for PVE4 units 
- panel meter for standard signals 
- freely scalable display with set points from –999 up to 9999 

 

P

1

2

3

6

7

4

Housing size 96x48

5

6

5

7

3

2

P

1

4

Housing size 96x24

P

4

1

2

3

7

Housing size 72x36

P

2

3

1

4

Housing size 48x24

1
2
3
4
5
6
7

Program key
Minus key
Plus key
7-segment display
Setpoint indication 1
Setpoint indication 2
Insertable dimensionstrip

 

Terminal connection 

10V

0/

4-

20m

A

0V

-

+

+

-

sensor

supply

(option)

analog

output

(option)

230V AC

115V AC

15

13

12

11

10

9

8

7

6

5

4

3

2

1

-

+

24V DC

or

14

or

setpoints

signal

inputs (DC)

S1

S2

10V

50V

0/

4-

20m

A

0V

-

+

signal inputs (DC)

analog-

output

(option)

9

8

7

6

5

4

3

2

1

-

+

24VDC

galv.

insulated

S2

6

5

CO

M

S1

10V

50V

0/

4-

20m

A

0V

signal inputs (DC)

analog

output

(option)

230V AC

115V AC

11

10

9

8

7

6

5

4

3

2

1

-

+

24V DC

or

or

setpoint

-

+

6

5

S2

CO

M

CO

M

NC

NO

S1

Housing size 96x48 and 96x24

Housing size 72x36

Housing size 48x24

NO

NC

COM

NO

NC

COM

 

Содержание PVE 4.001.1422B

Страница 1: ...segment display Setpoint indication 1 Setpoint indication 2 Insertable dimensionstrip Terminal connection 10V 0 4 20mA 0V sensor supply option analog output option 230V AC 115V AC 15 13 12 11 10 9 8 7...

Страница 2: ...22B Power supply 115 VAC terminal connection 11 L 10 N PVE 4 001 6722B Power supply 24 VDC terminal connection 11 L 10 L galvanic insulated TYPE ORDER NUMBER housing size 48x24 PVE 4 001 7782B Power s...

Страница 3: ...ayed value by pressing the W or V key 7 With program numbers 1 and 2 the applied voltage sensor calibration under program number 0 active can be saved by simultaneously pressing the P and W keys This...

Страница 4: ...de MIN MAX data Additional functions in normal mode for memory inquiry of the MIN MAX data The MIN MAX memory is a volatile memory in which after switching on the device or since the last erasure the...

Страница 5: ...nt no decimal point 4 Input of display time Display time measuring time Integrated measuring process 0 1 10 0 seconds 1 0 Analogue output optional 5 Input of final value for analogue output e g 300 0...

Страница 6: ...and V keys All further settings can be made by following the above procedure If you are in programming mode and do not press any key within 7 seconds the device automatically reverts from the programm...

Страница 7: ...sal bars Offset To program number 2 with P and V Connect measuring value 4mA To memorized value with W or V Memorize value with P and W Take over by display of transversal bars Decimal point To progra...

Страница 8: ...nciple S2 To program number 68 with P and V To memorized value with W or V Programming terminated 2 Factory calibration standard signals When using the factory calibration there is no need to apply a...

Страница 9: ...10 V at the analogue output Start of programming Switch on supply voltage Segment test Operating mode Calibration mode Enter program mode To memorized value with W or V Select parameter 1 for input 0...

Страница 10: ...230VAC 115VAC 24VDC Transmitter Input 0 10V Sensor supply minus Sensor supply plus Notes factory settings and error elimination After the supply voltage is switched on the device performs a reset inc...

Страница 11: ...V 0 20 mA 4 20 mA Range 72x36 0 10 V 0 50 V 0 20 mA 4 20 mA Range 48x24 0 10 V 0 50 V 0 20 mA 4 20 mA The maximum permitted value on the input clips is is 120 of the nominal value All ranges can be s...

Страница 12: ...een only for 96x48 4 digit indication 9999 digit Overflow indication of 4 transversal bars Display time adjustable from 0 1 10 0 seconds Ambient Working temperature 0 60 C conditions Storing temperatu...

Отзывы: