All the proximity Switches are powered directly to the PLC.
They are wired as follows:-
2 x Brown from FOS & FNS Proxy
Switch Live
Bank A,
Pin 8
Black from FNS Proxy Switch
Bank A,
Pin 6
Black from FOS Proxy Switch
Bank A,
Pin 7
2 x Blue from FOS & FNS Proxy
Switch Earth
Bank A,
Pin 5
2 x Blue from ROS & RNS Proxy
Switch Earth
Bank B,
Pin 4
Black from RNS Proxy Switch
Bank B,
Pin 2
Black from ROS Proxy Switch
Bank B,
Pin 3
2 x Brown from ROS & RNS Proxy
Switch- Live
Bank B,
Pin 1
Note:-
M12 Wiring Codes are as follows:-
Black = Output from the switch
Blue
= Earth
Brown = Live in
All proximity switches are PNP
Содержание SanuControl
Страница 1: ...Montracon Trailers SanuControl Double Deck Manual December 2015...
Страница 5: ......
Страница 12: ...The switches have covers fitted for protection...
Страница 13: ...When the lock is on the proximity switch is made the LED on the barrel of the proximity switch illuminates...
Страница 22: ...7 General Arrangement of the System...
Страница 23: ...8 Motor Relay Logic...
Страница 25: ...Main ve taken from the ve on the motor solenoid...
Страница 29: ...10 Hydraulic system The following shows the hydraulic system layout...