Section 2: Installation
Electrical Connection
IMPORTANT:
Electrical connections must be
carried out by a suitably qualified person and
in accordance with all relevant local building
and installation regulations.
•
See the rating label at the rear of the product for
the appliance’s load rating.
•
The cooker must be connected to a dedicated
circuit suitably rated for the load of the appliance
(see rating label at rear of appliance) as shown in
the wiring diagrams below. It must be connected
via a suitably rated cable to a double pole isolator
cooker switch also suitably rated for the appliance.
•
The electrical cable should not touch the hot parts
of the appliance.
The electrical cable (not supplied) should not be
routed through any area that may be affected by
heat from the oven, especially the area directly
behind the oven.
Minimum of 32 AMP Connection on a 6 mm cable.