Page 12 of 19
MW38-DV Modular Fireplace
P/N XG0112
Installation
Figure 21b.
Wiring schematic for optional fan kit.
115/1/60 Supply
G
L1 L2
Figure 21a.
Wiring for optional air circulating fan kit.
G
L2-WH
L1-BLK
Quick Connect
plug to motor
Wiring for the
optional
Fan Kit
All 38 Series Modular fireplaces feature an optional fan kit for
circulating heat into the living space.
Installations in Canada
which employ the fans must be electrically
grounded in accordance with
CSA C22.1
Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA
which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code,
ANSI/NFPA 70-1987.
For more information see the
Fan Kit Installation Guide
included
with the fan kit.
NOTE:
If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
Removing and Installing
the Door
Removing the door surround:
The door surround is held in place by two metal clips at the top, and
one magnet on each side. To remove the surround, pull the bottom
outwards and lift upwards until the slots "A" are clear of tabs "B" in
the door. You may need to use a flat screwdriver to pull the door
surround outwards.
(See figure 24a).
Removing the door:
To install/remove the glass door, simply attach/remove the ten (10)
machine screws that hold door in place
(See figure 24b).
Ensure that
a good seal is maintained when installing the door.
Figure 24a.
Removing or installing the door surround.
Glass door
and frame
Door surround
Tab 'B'
Slot 'A'
Magnet
Pull bottom of door
surround outwards
and upwards.
Glass door
& frame
Figure 24b.
Removing or installing the glass door.