Figure 15a.
(Control Panel Overview)
Figure 15b.
R520* / R620* Control Module
Left-side View
Right-side View
Figure 15c.
(Remote Switch Wire connection)
Wall Switch
LED Indicator
Fuse
110V
Power Supply
Wall Switch 10-conductor
communication
cable
110V
Outlet
Installing the Remote Switch
The
R520* / R620*
may be connected to a wall switch. The system
operates on a 24V AC.
DO NOT
connect this circuit to an external
power source.
The power cord from the power vent module plugs into the side of
this panel. The 20 foot low voltage wire is attached and connected
to this panel as well. Connect a single pole On/Off switch (Black and
White) to these two wires at a location of your choice,
(See Installing
the Remote Switch).
Montigo supplies 20' of low voltage wire to the electrical control panel.
Connect the two wire harnesses to a standard single pole ON/OFF
switch to the location of your choice. You may extend these wires
up to 100' in length with a wire of equal quality.
Installations in Canada
must be electrically grounded in accordance
with
CSA C22.1
Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA
must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code,
ANSI/NFPA 70.
Installation of Electrical Supply
The
R520* / R620*
is supplied with an external electrical control panel
pre-wired by the factory. The control box is connected to the fireplace
with a 20 foot long 10-conductor cable that will communicate with
the fireplace. The control panel should be located where it can be
accessed when the fireplace has been finished in.
Power Vent
Harness
R520 & R620 Power Vent Indoor Gas Fireplace
Page 26
XG0771 - 040513.3
Installation