background image

R324-STIOIndoorOutdoorVentlessGasFireplace

Page 20

XG0775 - 150204.1

Appendix

Appendix A: Warranty

TheWarranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo fireplace, 

there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control 

valve, fibre logs and Power Vent Module. The Glass, plated / painted finishes, and refractory lining are exempt from the warranty.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 

outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, 

and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies 

will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which 

are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All 

replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

QualificationsToTheWarranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo 

Gas Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas 

Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of 

local building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 

expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs 

or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty 

with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty 

lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.

The Companies Are Not Responsible For Work Done Without Written Consent

The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.

Dealers Have No Authority To Alter This Warranty

The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.

HowToRegisterAClaimAgainstWarranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably 

possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

 

The Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, 

specifications, prices and also to discontinue colors, styles and products.

Содержание R324-ST

Страница 1: ...zard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot surface General Warning Blank Gas bottles Watch for falling objects Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts Low temperature Strong magnetic field Optical r...

Страница 2: ...on 2 Framing 7 Section 3 Finishing 8 Section 4 Installing the Gas Line 11 Section 5 Electrical Connection 11 Section 6 a Removing Installing the Interior Screen and Door 12 Removing the Screen and Door 12 Section 6 b Removing Installing the Outside Screen and Door 13 Section 7 Installing the Firestones 14 Firestones 14 Optional River Rocks 14 Section 8 Start up Sequence 15 Section 9 Cleaning and M...

Страница 3: ...l installation and service work should be performed by a qualified or licensed installer plumber or gas fitter as certified by the state province region or governing body where the fireplace is being installed This installation operation and maintenance manual is applicable to the models described below Refer to your rating plate to verify included options Warranty and Installation Information See...

Страница 4: ...rrier removed for servicing an appliance must be replaced prior to operating the appliance Pre Installation Checklist Determine the desired install location of your fireplace See Section 1 Dimensions on Page 5 and refer to the Framing Section 2 for details Theelectricalpanelislocatedonthelowerrightsidewhenfacingtheinterior side of the fireplace Montigosupplies20 oflowvoltagewire whichcanbesplicedt...

Страница 5: ...STIO Indoor Outdoor Ventless Gas Fireplace Page 5 XG0775 150204 1 Installation Rating Plate Sample Figure A Rating Plate for R324 ST LBL1207D V5 0 R P VIEW_HSI_WITH SCREEN _DEC 11 2014 Teklynx LabelView Demo ...

Страница 6: ...ration mustbeconsideredwhen selecting the fireplace location Try to select a location that does not interfere with room traffic has adequate ventilation and offers an accessible pathway for Power Vent installation The fireplace dimensions are shown below Figure 1 Unit Dimensions 48 1219 39 1 8 994 39 3 8 999 35 3 4 906 23 3 8 594 23 1 4 590 25 1 8 638 26 3 4 679 21 5 8 549 27 1 2 699 14 1 2 369 9 ...

Страница 7: ...tends beyond both interior and exterior wall Note For all positions outside face must be positioned on OPEN non obstructed patio Outdoor Indoor 10 Min from grade 10 Min from grade 10 Min from grade X Y Unit must be 10 above grade on exterior side MODEL Sides Floor Indoor Floor Outdoor Top R324 STIO 1 2 0 10 3 Step 2 You may position the unit in framed opening to be flush to the interior wall Fig 3...

Страница 8: ...intotheintendedlocationfromtheoutsideof thebuildinguntiltheflashingisflushwiththebuildingexterior SeeFig 4a Nail the flashing to the exterior sheathing of the building STEP 5 Cover the flashing with approved waterproofing membrane brought to the 1 2 edge of the unit See Fig 4b STEP 6 Install steel stud construction or other non combustible to create1 2 clearanceonsidesand3 clearanceontopbeforeinst...

Страница 9: ...2 clearance all sides Figure 4c Install Steel studs for 1 2 clearance on sides and top Figure 4d Clearance above grade Non combustible Facing Combustible side IF 1 2 clearance is maintained Min 10 above grade 10 254 Minimum from Grade 1 2 13 3 73 5 Clearance to Combustible Non Combustible Flashing Combustible Header Combustible Sheathing Non Combustible Sheathing Indoor Side Outdoor Side Figure 4e...

Страница 10: ... 250 degrees Fahrenheit STEP3 Installnon combustiblefacingmaterialsuchascementboard or tile on the front inside face of the unit See Fig 4b STEP 4 Install drywall or other finishing material Figure 5 Interior framing Figure 5b Finished interior installation Figure 5a Interior face of unit non combustible Min Clearance 1 2 to combustibles Min Clearance 3 to combustible from top of unit from sides o...

Страница 11: ...vailable leak check solution DO NOT USE A FLAME OF ANY KIND TO TEST FOR LEAKS Pressure Requirements Gas Pressure Natural Gas Propane Minimum Inlet Pressure 5 5 W C 11 W C Manifold Presure 3 5 W C 10 W C After gas line is connected each appliance connection valve and valve train MUST be checked while under normal operating pressure with either a Liquid Solution or Leak Detection Device to locate an...

Страница 12: ...ttom fireplace door frame Figure 7c NOTE Read ALL the instructions supplied with the tool and follow the associated operating procedures Step 4 Still holding the Glass Removal Tool firmly remove the door outward and away from the Fireplace Figure 7d Step5 Placethedoorinasafelocationwhile maintenance cleaning or other operation are in progress NOTE Read ALL the instructions supplied with the tool a...

Страница 13: ...d out Figure 7f Lifting screen frame off fireplace Step 3 Removethescrewsthatsecurethescreentotheunit Makesuretoholdthe screensecurleyasyouremovethelastfewscrewstopreventthescreenfromfalling Figure 7g Removing screws that secure screen Figure 7h Removing screws that secure door REVISIONS REV DESCRIPTION DATE CHANGED BY 1 16 DWG NO WEIGHT R3 Finish MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES FRACT...

Страница 14: ...the glass door or with a broken glass door NOTICE TheC ViewResidentialR324STIOfireplacehastheoptionofinstallingthesupplied glass Firestones other colored glass media or cultured rocks Firestones The C View Residential R324 STIO fireplace is supplied with Glass Firestones To installtheFirestonesremovetheDoorandtrimasshowninthepreviousInstruction Followtheseinstructionstoensureallpartsareremovedorre...

Страница 15: ...ndoor Outdoor Ventless Gas Fireplace Page 15 XG0775 150204 1 Operation Section 8 Start up Sequence TO TURN OFF GAS TO APPLIANCE LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING Heat Sensor Conmustion Air ...

Страница 16: ...ormal condition and is the result of burning of protective coatings on new metal Glass must be cleaned periodically to remove any film which is a normal by product of combustion which may be visible Film can easily be removed by removing the door as shown on Page 11 Handle the door carefully and clean it with non abrasive glass cleaners One of the most effective products is Kel Kem Use a vacuum cl...

Страница 17: ...Gas Valve Flue Gas Switch R3 R1 R2 R1 Wht Grn Blk Wht Brn Blk Blu Wht BLK BLK Wht Wht Red Red Q R T S U V W X Wht Blk Blu Blu 3 1 Brown Blu Red Blu Blk Black Black White Blu Grey X W V U T S R Q WS NC R3 R2 24V 110V Grey PV Blu Brn Red 0 2in WC Post Purge Timer Prepurge Timer Main Power NO Flue Temp Limit Switch 300 F C Grn Fuse 5A 25OVAC ...

Страница 18: ...p 4 Lift control panel cover out to expose controls Figure 11e Exposing controls under control panel Figure 11f Control box controls Figure 11g Control box controls Vacuum Switch Fuse Fan Speed Controller Prepurge Timer Transformer Vacuum Switch Relay Power Relay Thermal Switch Relay Capacitor Gas Valve Figure 11b Note placement of rating plate Figure 11c Removing screws from each side of the cont...

Страница 19: ... RPA003 30 LP Pilot Assembly RPA004 30 Power Vent Control Box RESCB2 Replacement Screen RSCR320 Fuse AGC 5Amp EC1122 275 deg F Manual Reset Switch EC1073 Vacuum Switch REC1226 Outdoor Glass for fireplace without screen RD324ST01 Outdoor Glass for fireplace with screen RDT324OD Indoor Glass RD324ST02 Outdoor Screen RSCR324OD Indoor Screen RSCR324ID Replacement Parts ...

Страница 20: ...d by The Companies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sol...

Страница 21: ...inimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall no...

Страница 22: ...XG0775 150204 1 R324 ST Indoor Outdoor Gas Fireplace USA ...

Отзывы: