Installation

Page 3

XT0021 -151127.1

A. Disconnect wire from existing module:

1.  Remove valve blind and glass door.

Figure 3 

Control module with wires

B. Control Module Connection:

1.  Connect the Manual ON/OFF switch to X4.

Figure 4 

X4 plug on control module

Figure 5

 Attach switch bracket to front of fireplace

C. Main ON/OFF Switch Installation:

1.  Position the Main/off Switch bracket on the right leg of the 

firebox as shown in 

Figure 5

 

and Figure 6

2.  Using the two selftapping screws supplied attach the bracket. 

See 

Figure 6.

3.  Feed the switch and the wires through the slot in the bracket as 

shown and install the switch to the bracket. See 

Figure 7

.

4.  Secure the wires to the floor of the fireplace using the supplied 

cable tie and cable tie mounts.

5.  Attach the "Main ON/OFF" label supplied to the valve bracket.

Figure 6

 Attach switch bracket to front of fireplace

Figure 7

 Attach switch to bracket.

X4 Control 

Module

Connect Manual ON
OFF switch here

Содержание Proflame 2

Страница 1: ... property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If y...

Страница 2: ... a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with this kit Note Upon successful inst...

Страница 3: ...racket on the right leg of the firebox as shown in Figure 5 and Figure 6 2 Using the two selftapping screws supplied attach the bracket See Figure 6 3 Feed the switch and the wires through the slot in the bracket as shown and install the switch to the bracket See Figure 7 4 Secure the wires to the floor of the fireplace using the supplied cable tie and cable tie mounts 5 Attach the Main ON OFF lab...

Страница 4: ...lack wires from the battery holder to the red and black wires from the valve harness See Figure 10 Figure 8 Attach switch to bracket Figure 9 Battery holder E Operation with Backup Battery 1 Install the four supplied AA batteries to the battery holder CAUTION Please note battery orientation while installing them Incorrect orientation may damage battery cause fire hazard and the fireplace may not f...

Страница 5: ... or third time depending on prevailing temperatures or altitude When in CPI mode the pilot also keeps the system warm During a cold start condensation will normally form on the inner glass surface of the door This condensation will quickly dry however the condensation tends to run down the glass and cause some streaking CPI mode helps to resolve this issue If CPI mode is used during the winter mon...

Страница 6: ...XT0021 151127 1 Proflame 2 Upgrade Kit ...

Отзывы: