Page 10
XG0305
MD34-BV Homefire
Maintenance
CAUTIONS
Fireplace gas control must be in the “OFF” position and pilot
and main burners extinguished when cleaning appliance with
a vacuum.
Doors and logs can get very hot. Handle only when cool.
General
Have the fireplace installation inspected yearly, including a visual
check of the vent system, the burner and the pilot flame. For your
convenience a 1/8" manifold pressure tap is supplied on the gas
valve for a test gauge connection. See Figure 12.
For
Natural Gas
this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.
For
Propane Gas
this appliance requires a minimum inlet pres-
sure of 11" W.C. and a manifold pressure of 10" W.C.
Always keep the fireplace area clear and free of combustible
materials, as well as gasoline and other flammable vapours and
liquids.
Do not use this appliance if
any part has been under water
. Imme-
diately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control
which has been under water.
Operation
Lighting Instructions
See pages 8 and 9.
Burner Adjustment
The MD34-DV fireplace is equipped with an adjustable burner, al-
lowing you to raise or lower the flames. Operating the control knob
as described below will adjust both the main burner and the ember
burner.
To raise the flame height, turn the black knob (located behind the
lower trim)
counterclockwise
.
To lower the flame height, turn
clockwise
.
Gas Control Knob
(Shown in "Pilot" postion.)
'Hi-Lo' Adjustment Knob
Figure 11.
'Hi-Lo' Adjustment on Model MD34-BV gas valve.
Cleaning
When the fireplace is first activated, there may be some smoking and
a visible film may be left on the glass. This is a normal condition, and
is the result of burning of protective coatings on new metal.
Glass must be cleaned periodically to remove any film (which
is a normal biproduct of combustion) which may be visible. Film
can easily be removed by removing the door, as shown on page
7. Handle the door carefully, and clean it with non-abrasive glass
cleaners. One of the most effective products is Kel Kem.
Silicone seals on inner door during initial firing will "off gas", leav-
ing a visual deposit of a white substance on combustion cham-
ber walls. This can easily be removed using normal household
products.
Use a vacuum cleaner or whisk broom to keep the control com-
partment, burner, and firebox free from dust and lint.
Logs may be cleaned periodically with a vacuum to remove soot
or other contaminates. Do not attempt to move the 2 large logs
when cleaning. They are extremely fragile and will break easily.
WARNING:
Do not attempt to clean glass when hot.
Do not clean glass with abrasive materials as any glass etch-
ing may cause premature glass failure.