background image

Page 10

XG0305

MD34-BV Homefire

Maintenance

CAUTIONS

  Fireplace gas control must be in the “OFF” position and pilot 

and main burners extinguished when cleaning appliance with 
a vacuum. 

  Doors and logs can get very hot. Handle only when cool.

General

  Have the fireplace installation inspected yearly, including a visual 

check of the vent system, the burner and the pilot flame. For your 
convenience a 1/8" manifold pressure tap is supplied on the gas 
valve for a test gauge connection. See Figure 12.  

  For 

Natural Gas

 this appliance requires a minimum inlet pressure 

of 5.5" W.C. and a manifold pressure of 3.5" W.C.

  For 

Propane Gas 

this appliance requires a minimum inlet pres-

sure of  11" W.C. and a manifold pressure of 10" W.C.

  Always keep the fireplace area clear and free of combustible 

materials, as well as gasoline and other flammable vapours and 
liquids. 

  Do not use this appliance if 

any part has been under water

. Imme-

diately call a qualified service technician to inspect the appliance 
and to replace any part of the control system and any gas control 
which has been under water.

Operation

Lighting Instructions

See pages 8 and 9.

Burner Adjustment

The MD34-DV fireplace is equipped with an adjustable burner, al-
lowing you to raise or lower the flames. Operating the control knob 
as described below will adjust both the main burner and the ember 
burner.

  To raise the flame height, turn the black knob (located behind the 

lower trim) 

counterclockwise

.

  To lower the flame height, turn 

clockwise

.

Gas Control Knob

(Shown in "Pilot" postion.)

'Hi-Lo' Adjustment Knob

Figure 11.

 

'Hi-Lo' Adjustment on Model MD34-BV gas valve.

Cleaning

When the fireplace is first activated, there may be some smoking and 
a visible film may be left on the glass. This is a normal condition, and 
is the result of burning of protective coatings on new metal.

  Glass must be cleaned periodically to remove any film (which 

is a normal biproduct of combustion) which may be visible. Film 
can easily be removed by removing the door, as shown on page 
7.  Handle the door carefully, and clean it with non-abrasive glass 
cleaners. One of the most effective products is Kel Kem.

  Silicone seals on inner door during initial firing will "off gas", leav-

ing a visual deposit of a white substance on combustion cham-
ber walls. This can easily be removed using normal household 
products.

  Use a vacuum cleaner or whisk broom to keep the control com-

partment, burner, and firebox free from dust and lint.   

  Logs may be cleaned periodically with a vacuum to remove soot 

or other contaminates. Do not attempt to move the 2 large logs 
when cleaning. They are extremely fragile and will break easily.

WARNING:

Do not attempt to clean glass when hot.
Do not clean glass with abrasive materials as any glass etch-
ing may cause premature glass failure. 

Содержание MD34-BV Homefire Plus

Страница 1: ...or s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper installation adjustment altera tion service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier For Your Safety Do not store or use gasoline or ...

Страница 2: ...tory built gas fireplaces Installation repairs should be done by a qualified contractor Installations in Canada must conform to the current CAN CGA B 149 1 and 2 Gas Installation Code and local regulations If the optional air circulating fan kit is installed it must be electrically grounded in accordance with CSA C22 1 Canadian Electrical Code Part 1 and or Local Codes Installations in the USA mus...

Страница 3: ... 15 32 30 38 Figure 2 Framing dimensions Framing 33 15 3 4 39 When sheetrock is not used behind the fireplace fram ing depth may be reduced to 15 Figure 3 Corner framing dimensions 22 42 0 clearance to corners only 33 59 3 8 Installing a Shelf Over the Fireplace When installing a shelf over the top of the fireplace the minimum al lowable clearance from the top of the fireplace to a shelf is 16 Pro...

Страница 4: ...er brass trim may be connected to a wall switch The valve generates its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 12 for wiring requirements Note The switch location must not exceed 30 from the fireplace Figure 4 Gas line access During any pressure testing of the gas supply piping that excedes 1 2 psig 3 5 kPa the applian...

Страница 5: ... of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Please be aware temperatures over the mantel will rise above nor mal room temperature and walls above fireplace may be hot to touch We recommend careful consideration be given to the effects of elevated mantel temperatures which may be in excess of product design for example candles plastic ...

Страница 6: ...L2 Figure 7a Wiring for optional air circulating fan kit Figure 7b Wiring schematic for optional fan kit Installing the Log Set The ME34 BV is supplied with four 4 soft fibre logs Logs A and B are permanently attached to a fibre base which is pre installed by the factory To install the two small logs C and D simply place them onto their mating positions as shown in figure 8a below When log set is ...

Страница 7: ...y reverse the steps above Figure 9 MD34 BV insert INSET 1 Tab INSET 2 Mounting Bracket Venting Plate Front Slot Removing and Installing the Door Removing the door surround The door surround is held in place by two metal clips at the top and one magnet on each side To remove the surround pull the bottom outwards and lift upwards until the slots A are clear of tabs B in the door You may need to use ...

Страница 8: ...n Model MD34 BV 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up lower trim 1 Turn off remote switch 2 Flip down lower trim 1 STOP Read the safety information above on this label 2 Flip down lower trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you then smell gas STOP...

Страница 9: ...to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down lower trim 3 Turn the switch on the gas control to Off 4 Flip up trim 1 STOP Read the safety information above on this label 2 Flip down lower trims 3 Turn switch on th...

Страница 10: ...cribed below will adjust both the main burner and the ember burner To raise the flame height turn the black knob located behind the lower trim counterclockwise To lower the flame height turn clockwise Gas Control Knob Shown in Pilot postion Hi Lo Adjustment Knob Figure 11 Hi Lo Adjustment on Model MD34 BV gas valve Cleaning When the fireplace is first activated there may be some smoking and a visi...

Страница 11: ... rm er LineVo lt Sup p ly Rep lace SV9500 SV9600 Saveo ld Ig niter Flam e Ro da ssem b ly fo rservice INSET HSI Terminals C H EC K Linevo ltag ep o w er Lo wvo ltag e transfo rm er Lim itC o ntro ller Therm o stat W iring a irp ro vingsw itcho n co m b ustio nairb lo w ersystem Ventd am p er ifused iso p en andendsw itchm ad e Gas Control Valve Pilot Burner Adjustment 1 Locate Pilot Adjustment Scr...

Страница 12: ...ts not manufactured or supplied by The Companies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and und...

Страница 13: ... Horizontal Trim Kits 2 4 piece fibre logset Available Options and Accessories 3 3 Fan Pack 4 Variable Speed Blower Kit 5 Hand Held Remote Control 6 3 Piece Picture Frame Surround PFO 7 4 Piece Picture Frame Surround PFS 8 Door Cover Square DF0 9 Door Cover Arched DFA 2 3 4 6 7 5 8 9 ...

Страница 14: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0305 Rev 03 09 2002 ...

Отзывы: