Page 23
P/N XG0205
M40DV-PFC Peninsula Gas Fireplace
Appendix B - M40DV-PFC-MH Mobile Home
This appliance may be installed as an OEM installa-
tion in a manufactured home (USA only) or mobile
home and must be installed in accordance with the
manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280, in the United States or The Mobile Home
Standard, CAN / CSA Z240 MH Series, in Canada. This
appliance is only for use with the type(s) of gas indi-
cated on the rating plate. A conversion kit is supplied
with the appliance.
Gas Control Valve
The following gas control valve is installed on the M40DV-PFC-MH.
Figure B1. Sit Nova 820 gas valve
.
Manifold Pressure
Test Connection
Pilot Adjustment Screw
Inlet
Pressure
Power
Generator
Wall Switch
M40DV-PFC-MH Mobile Home
The mobile home option is a factory installed on the M40DV-PFC-MH
gas fireplace, and is for use in a manufactured or mobile home.
The standard M40DV-PFC or the M40DV-PFC-I equipped with
Hot Surface Ignition (HSI) are not approved for use in mobile or
manufactured homes.
The M40DV-PFC-MH is rated for:
Natural Gas at 30,000 BTU/H (8.79 Kilowatts) max. input, and
24,000 BTU/H (7.03 Kilowatts) min. input.
Propane at 30,000 BTU/H (8.79 Kilowatts) max. input, and
24,000 BTU/H (7.03 Kilowatts) min. input.
Conversion Kits
The M40DV-PFC-MH mobile home appliance is field convertible
between Natural Gas (NG) and Propane (LP).
To convert from Natural Gas to Propane order conversion kit #
RCV725.
To convert from Propane to Natural Gas order conversion kit #
RCV825.
Conversion kits are available for standard M40DV-PFC conversion
between Natural Gas (NG) and Propane (LP).
A manufactured home (USA only) or mobile home
OEM installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280, or when such a standard is not applicable,
the Standard for Fire Safety Criteria for Manufactured
Home Installation Sites and Communities, ANSI/NFPA
501A, in the United States or the Mobile Home Stand-
ard, CAN / CSA Z240 MH Series, in Canada.