![Montigo M38BV-ST Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/montigo/m38bv-st/m38bv-st_installation-and-operation-manual_1830656006.webp)
Page
M38BV-ST B-Vented Fireplace
Installation
Wiring
Figure 6b.
Wiring schematic for fans.
Gas Control and Pilot Wiring
Figure 5.
Wiring for the M38BV-ST-I with Honeywell gas control and
pilot.
Fans
The M38BV-ST is equipped with 4 fans for circulating heat into
the living space. Installations in Canada
must be in accordance
with
CSA C22.1
Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA
must be in accordance with local codes
or, in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70-1987.
NOTE:
If any of the original wire supplied with the appli-
ance is replaced, it must be replaced with the same
type, or its equivalent.
Installing the Log Set
The
M38BV-ST
is supplied with five (5) fibre logs. To install, simply
place log
"A's"
rectangular shaped extension into the log mounting
slot located on rear wall of the burner assembly. Place log
"B"
onto
front log slots of the burner assembly. Place log
"C"
and log
"D"
onto
the mating positions as shown in Figure 7a below
.
When log set is
installed it should look like Figure 7b.
Figure 7b.
Log Installation - Step 2.
Log 'A'
Log 'B'
Log 'C'
Log 'D'
Figure 7a.
Log Installation - Step 1.
Log 'E'
WARNING
:
If logs are not placed properly, excessive
sooting will result.
Figure 6a.
Wiring for fans.
Fan motors
Fan
mot
ors
M38BV-ST-I
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junction Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grnd Screw
115/1/60 Supply
G
L1 L2
G
L1-WH
L2-BLK