Installation
Section 4: Wiring
Installing the On/Off Wall Switch
The Phenom gas valve may be connected to a wall switch. Do NOT
connect any external power to the remote switch. The valve will generate
its own power on a millivolt circuit or will draw its power from an AC
Connection inside the fireplace, depending on the model of the unit.
Use only low voltage wire, and DO NOT connect any external power
to the remote switch.
NOTE:
The switch location must not exceed 30' from the fireplace.
NOTE:
If any of the original wire supplied with the appliance is replaced,
it must be replaced with the same type, or its equivalent.
Figure 17.
Wiring diagram for L38DF, L42DF, L52DF with SIT Proflame 2 Electronic Ignition
Figure 17.b
Wiring Diagram for SIT Nova 820 gas
and pilot.
1.5V AA type
1.5V AA type
1.5V AA type
1.5V AA type
BLACK
WHITE
GREEN
To PPO
SPARK
SENSOR
RED
BLACK
BATTERY
PACK
TO ON/OFF
WALL SWITCH
YELLOW/GREEN
ORANGE
GREEN
6
10
4
6
3
4
OPTIONAL CPI/IPI SWITCH
BLUE
WHITE
X1
X5
X4
X3
X2
LED Lights
LED1 - Red LED
LED2 Amber LED
3.15A FUSE
SW1
BLUE
RED
OPTIONAL
X10
X11
X12
X13
78 "
8 12 "
3 58 "
BLACK
LED LIGHTS
LED1 - RED LED
LED2 AMBER LED
TO PPO
3.15A FUSE
WHITE
GREEN
SPARK
SENSOR
BLUE
YELLOW/GREEN
ORANGE
GREEN
OPTIONAL CPI/IPI SWITCH
WHITE
TO ON/OFF
WALL SWITCH
POWER
GENERATOR
WALL SWITCH
PILOT
ADJUSTMENT
SCREW
HI-LO
ADJUSTMENT
KNOB
INLET
PRESSURE
MANIFOLD
PRESSURE TEST
CONNECTION
BLACK
RED
RED
BLUE
1.5V AA TYPE
1.5V AA TYPE
1.5V AA TYPE
1.5V AA TYPE
BATTERY PACK
GAS CONTROL
KNOB (SHOWN
IN PILOT
POSITION)