Page 10
HW42DF Gas Fireplace
Part No. XG0191 - 031010
Installation
Figure 17.
Vertical venting with 2 offsets (1 offset= two
90° bends).
C. Vertical (Corner) Installations
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the
PXT-18 to suit, and attach it to the PEL-45. Slide the fireplace into
position and attach to the termination.
Important: Some models are not available to be
installed in a rear vent application. Please refer to
the model specifications on page 2 of this manual.
Figure 18.
Corner installation.
Figure 19.
Flex installation.
(NG Models Only)
C. Vertical (Corner) Installations
- 45° or less.
Use an MTO-3/PTO-3 termination and an MFL-1/PFL-1 or PFL-2/
PFL-2 (12" or 24" compressed length) and a frame, if appropriate.
Flex may be turned to obtain desired degree of angle required but
must not exceed 45°.
Note: Through the wall venting kits are also available for both
the Straight and the Corner Installation.
The Kit includes a heat
sheild, a PFL-18 (f/f) flexible pipe, and a termination with or without
a mounting frame.
PEL-45 Elbow
PEL-90 Elbow
PXT-18
Rear Vent Venting Runs
The
HW42DF Rear Vent
has Only One possible installation which
requires vertical lift. This installation requires that you install the RHS101
heat shield.
Heat Shield
The heat shield (RHS101) must be used on
All installations through
the wall
, at the point where the vent pipe connects to the termination.
With the heat shield, proper vent clearances can be maintained.
The
heat shield is not included with the fireplace.
To install the heat shield, slide one section over the vent pipe on the inside
of the wall opening, with the circular portion
inside the wall cavity
. Screw
the shield in place over the wall opening. Install the second section on
the outside of the wall opening sliding the circular portion into the wall
opening. Refer to Figure 22 & Figure 24.
B. Multi-Elbow Installations
For more difficult installation situations, the
HW42DF
Rear Vent may be
installed with two - 90° elbows and up to 15' of horizontal run. If using
this installation option, you must adhere to the following guidelines:
the first 90° elbow must be placed directly on the flue collar
you must have a minimum vertical lift of 50" (measured from the
hearth)
your vent run must fall within the limits set by Figure 22.
Before you install any venting, you must determine whether the venting
run will be acceptable. Unacceptable venting can affect the fireplace's
combustion.
Содержание HW42DF
Страница 25: ...Page 25 HW42DF Gas Fireplace Part No XG0191 031010 Notes ...
Страница 26: ...Page 26 HW42DF Gas Fireplace Part No XG0191 031010 Notes ...
Страница 27: ...Page 27 HW42DF Gas Fireplace Part No XG0191 031010 Notes ...
Страница 28: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0191 031010 ...