background image

H*42DF ST Indoor Gas Fireplace

Page 18

XG0237 - 150204

Installation

Models Included

H42DFSTN-F

H42FSTL-F

HL42DFSTN-F

HL42FSTL-F

Models Included

H42DFSTN-I

H42DFSTL-I

HL42DFSTN-I

HL42DFSTL-I

Section 4: Wiring

Figure 15.  

Wiring Diagram for the 

SIT Proflame 2

 Electronic Ignition

Figure 17.  

Wiring with 

Honeywell 

gas control and pilot.

Honeywell (Q3450)
Pilot Assembly

Pilot Electrical
Harness Connector

Honeywell Gas
Control (SV9501M)

Gas Control
Connector

Junction Box

115VAC
24VAC

40 VA
Transformer

Black

White

Green

Gnd Screw

Wall Switch

Fan Plug
Receptacle

Manifold Pressure

Test Connection

Wall Switch

Power 

Generator

Pilot Adjustment Screw

Inlet Pressure

'Hi-Lo' Adjustment Knob

Gas Control Knob

(Shown in “Pilot” position)

Figure 16. 

 Wiring Diagram for 

SIT Nova 820

 gas and pilot. 

Models Included

H42DFSTN

H42DFSTL

1.5V AA type

1.5V AA type

1.5V AA type

1.5V AA type

BLACK

WHITE

GREEN

To PPO 

SPARK

SENSOR

RED

BLACK

BATTERY

   PACK

TO ON/OFF

WALL SWITCH

YELLOW/GREEN
ORANGE
GREEN

6

10

4

6

3
4

OPTIONAL CPI/IPI SWITCH

BLUE

WHITE

X1

X5

X4

X3

X2

LED Lights
LED1 - Red LED
LED2 Amber LED

3.15A FUSE

SW1

BLUE
RED

OPTIONAL

X10

X11

X12

X13

Содержание H42DF ST

Страница 1: ...Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot surface General Warning Blank Gas bottles Watch for falling o...

Страница 2: ...n 3 2 1 Venting Layout 11 Section 3 3 Installing a Wall Mounted Direct Vent 13 Termination 13 Section 3 3 1 Venting Layout Wall Mounted Termination 14 Section 3 3 2 Venting Components 16 Section 3 3 3 Heat Shields 17 Section 4 Wiring 18 Section 5 Installing the Gas Line 20 Section 5 1 FUEL CONVERSION 20 Section 5 2 GAS PRESSURE 20 Section 5 3 GAS CONNECTION 20 Section 6 Finishing 21 Section 7 Scre...

Страница 3: ...rnings and notices throughout this manual intended to ensure your safety Thismanualcoversinstallation operationandmaintenance Lighting operation and care of this fireplace can be easily performed by the homeowner All installation and service work should be performed by a qualified or licensed installer plumber or gasfitter as certified by the state province region or governing body where the firep...

Страница 4: ... accordance with these Instructions Carefully read all the Instructions in this manual first Consult the Local Gas Branch to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure this fireplace is installed in compliance with the manufacturers instructions and all applicable codes BEFORE YOU START Installation and repairs should be d...

Страница 5: ...dplumbing Safety as well as efficiency of operation should be considered when selecting the fireplace location Select a location that does not interfere withroomtraffic hasadequateventilationandoffersanaccessiblepath for Direct Vent installation The fireplace dimensions are shown below Figure 1 Fireplace dimensions Tolerance Top View Front View Both Sides Typical Side View 40 1 2 1029 4 3 4 122 5 ...

Страница 6: ...ation Rating Plate Sample H42DF ST Figure A Rating Plate for standing pilot SIT Figure B Rating Plate for IPI eletronic ignition LBL1205 V6 1 Stand Pilot Screen DEC06 2014 Teklynx LabelView Demo LB1223 V5 1 SIT IPI with screen DEC06 2014 Teklynx LabelView Demo ...

Страница 7: ...ation Rating Plate Sample HL42DF ST Figure A Rating Plate for standing pilot SIT Figure B Rating Plate for IPI eletronic ignition LBL1205 V6 1 Stand Pilot Screen DEC06 2014 Teklynx LabelView Demo LB1223 V5 1 SIT IPI with screen DEC06 2014 Teklynx LabelView Demo ...

Страница 8: ...ove over fireplace Non Combustible Nail ing Flange supplied Both sides Typical See figure Top Vent 49 40 10 6 Figure 3 Securing the fireplace to the framing cleats Frame the fireplace cavity according to Figure 2 Slide the fireplace into the cavity Tack four studs Vertical broken line in place shown in Fig 3 Secure the fireplace in position by nailing into these cleats 6 45 rough opening 24 49 46 ...

Страница 9: ...r Mantel Figure 6 Installing the Nailing Flange Extension Both sides typical 6 Installing the Nailing Flange Extension Once the fireplace is placed into the rough framed opening the supplied Nailing Flange Extension Part No H42074 must be fasten securely into place with nails or wood screws as shown in Figure 6 The Supplied nailing extension must be placed along the top edge of the fireplace and s...

Страница 10: ...T be selected such that it is the highest point in the venting assembly It should also be selected such that it provides the shortest vent run possible Should it be impossible to ensure that the termination is the highest point or should it be impossible to meet the venting guidelines laid out below please contact your Montigo dealer to discuss power venting options NOTES FOR PLANNING VENTING Vent...

Страница 11: ...materials see Figures 8 to 8c Termination location must be a minimum 6 from a mechanical air inlet Terminationlocationmustbeaminimum18 fromaparapetwall For a more detailed diagram of allowed termination locations see Appendix A A maximum of two offsets each offset is made up of 2 90 bends may be made for vertical vent runs FirestopsmustbeinstalledasrequiredbyNational localcodes Ensure all horizont...

Страница 12: ...0204 Installation Figure 8c Side vent Roof mounted venting 1 90 bend PEXT Solid Section PVTK1 Termination 12 Max Note Imagesareshownwithoutscreensforclaritypurposes However your fireplace should not be operated without proper installation of screens ...

Страница 13: ...n of the termination 1 Frame the BSR opening to 12 x 12 2 Secure the BSR Frame to the exterior sheathing of the structure 1 Frame the MOSR opening to 12 x 12 2 Fasten the MOSR frame to the interior side of the studs concrete or finished wall construction using a minimum of 4 screws 3 Insert the termination into the MOSR frame as shown here from the inside and attach to the MOSR by installing a min...

Страница 14: ... mounted terminations Figure 11 Figure 11b Top Vented wall mounted Multi elbow installation See Venting Graph for Top vent wall mounted terminations Figure 11 Section 3 3 1 Venting Layout Wall Mounted Termination Selection of components and details of venting layout should adhere to the following guidelines Vent terminations must not be recessed in walls or siding For Heat Shield requirements see ...

Страница 15: ...f the X falls on or above the top boundary of the shaded area the installation is acceptable Example A Acceptable Installation If the vertical dimension from the hearth is 120 and the horizontal run to the wall flange of the vent termination is 138 this would be an acceptable installation Example B Unacceptable Installation If the vertical dimension from the hearth is 48 and the horizontal run to ...

Страница 16: ...lt your Building Envelope Engineer or Waterproofing Consultant for further recommendations Section 3 3 2 Venting Components The following components and associated Montigo part numbers for installation of a roof or wall mounted termination Use only Montigo Vent Components Use of non Montigo parts will VOID the warranty and may impede operation of the fireplace Use any combination of rigid and flex...

Страница 17: ...on Drywall sheetrock RHS101 Heat Shield inner Section RHS101 Heat Shield Outer Section Vent pipe from fireplace Outer Shield 10 1 4 3 8 Min Both sides Typical 3 8 Min 3 8 Min Combustible Framing 12 x 12 Inner Shield 9 3 8 Installing a Wall Mounted RHS101 Heat shield The RHS101 Heat shield MUST be used where the Termination falls within 36 horizontal or 60 vertically from the fireplace Figure 13a U...

Страница 18: ...x 115VAC 24VAC 40 VA Transformer Black White Green Gnd Screw Wall Switch Fan Plug Receptacle Manifold Pressure Test Connection Wall Switch Power Generator Pilot Adjustment Screw Inlet Pressure Hi Lo Adjustment Knob Gas Control Knob Shown in Pilot position Figure 16 Wiring Diagram for SIT Nova 820 gas and pilot Models Included H42DFSTN H42DFSTL 1 5V AA type 1 5V AA type 1 5V AA type 1 5V AA type BL...

Страница 19: ...valve may be connected to a wall switch Do NOT connect any external power to the remote switch The valve will generate its own power on a millivolt circuit or will draw its power from an AC Connection inside the fireplace depending on the model of the unit Use only low voltage wire and DO NOT connect any external power to the remote switch Refer to Figure 15 16 or 17 for wiring requirements NOTE T...

Страница 20: ...ervice shut off valve be located in an accessible location to isolate the gas supply Only install gas shut off valves approved for use by the state province or other governing body in which the fireplace is being installed Section 5 3 GAS CONNECTION See Figure 19 below for location of gas line access Flexible gas connectors must not exceed 3 feet in length unless allowable within local regulations...

Страница 21: ...will rise above normal room temperature and walls above fireplace may be hot to touch Side wall clearances are 3 Combustible surrounds may be installed with 3 clearance to the side of the fireplace as shown in Figure 21 Do not operate this fireplace without the glass door or with a broken glass door NOTICE Do not use ammonia based or abrasive cleaners on the glass they will permanently etch the su...

Страница 22: ...s Holdthescreensatanangleawayfromthefireplace and locatetheScreenBottomTabsatthelowercornersofthe screen PlacethescreenintotheScreenTabRecepticles in the lower section of the fireplace Make sure the tabs and screens are lowered all the way down into the Screen Tab Recepticles on the fireplace Then push each Upper Screen Stud on the top corners of the screen into the Upper Screen Stud Receptables i...

Страница 23: ...orizontal Access Panel 2 Step 5 Ensure the tool is firmly in the lower end of the slot as shown Then pull toward you Caution hold the tool securely 3 Step 6 Pull hard if necessary to release the spring ten sion Caution The latch springs back with force hold the tool securely 4 Step 7 Remove the tool from the latch slot Ensure the latches are hanging freely the hook end is released from the bottom ...

Страница 24: ...or on either side usually midway and lift upward lift the door carefully up and away from the front of the fireplace See Figures22g PlacetheDoorasideinasafeplacewhilemaintenance and or cleaning is being performed Figure 22g Removing and installing the glass doors Both Sides Typical Removing the Door WARNING When installing the fireplace gas lines fittings accessories or any other objects cannot im...

Страница 25: ...inFigure24c Figure 23b Log D Installation Figure 23a Log C Installation Log B Log C Log D Log A Log C Log D Front of Fireplace Figure 23c Completed Installation Installing the Ember Material The ember material is supplied in two packages Place the material evenly within the internal area of the burner next to logs A and B Refer to figure 23a Ensure that the burner holes of the burner are not cover...

Страница 26: ... Propane Fireplaces The HL42DF ST fireplace is supplied with firestones Remove the Door s as shown on page 20 Follow these instructions to ensure all parts are removed or replaced as required Once the glass door s is removed place the firestones randomly across the pan as described in Figure 24 to 24a Figure 24 Completed firestone installation Second Gen burner shown Note DO NOT place ANY fireston...

Страница 27: ...n remote switch to ignite fire NOTE Gas control knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force with American Flame Electronic Ignition For Your Safety READ BEFORE LIGHTING If you cannot reach your gas supplier call the Fire Depart ment C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do...

Страница 28: ... go to the next step 6 Turn fireplace ON using wall switch or remote control 7 If the Fireplace does not light the System will cycle through two trials one minute audible clicking thirty seconds of silence and then another one minute of audible clicking If the system locks out due to inadequate gas flow refer to Troubleshooting in instruction guide 8 After completion of the information in the Trou...

Страница 29: ... Wait 5 minutes to clear out any gas If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 5 Turn switch on the gas control to ON NOTE This unit is equipped with an ignition system that lights the pilot burner automatically Do not attempt to light the pilot by hand 6 Turn on wall switch 7 Replace the lower Horizontal access panel 8 ...

Страница 30: ...arefully and clean it with non abrasive glass cleaners One of the most effective products is Kel Kem Silicone seals on inner door during initial firing will off gas leaving a visual deposit of a white substance on combustion chamber walls This can easily be removed from the chamber walls using normal household products Use a vacuum cleaner or whisk broom to keep the control compartment burner and ...

Страница 31: ...tch typicallylocatedbelowthevalvecover and turn ON 2 Ensure main power is ON or new batteries are installed in the remote control and backup battery pack if available 3 Check the 3 15A fuse in the control box and replace if necessary Pilot Igniter sparking but Pilot burner will not light 1 Verify the Inlet and Manifold Gas Pressure are within acceptable limits 2 Check all connections to gas valve ...

Страница 32: ...urner Contact Local Montigo Dealer LP Burner Thermocouple RTC182 Thermopile RPG001 Piezo Ignitor PIEZO Pilot Tubing RPTA03 Door RDTH42 Replacement Screen RSCH42 SIT IPI Proflame 2 Replacement Parts List H42DF ST HL42 ST Log Set RLGSH42ST N A NG Gas Valve Hi Low RGC3044 LP Gas Valve Hi Low RGC3045 NG Gas Valve with stepper motor RGC3033 LP Gas Valve with stepper motor RGC3034 NG Pilot Assembly RPA0...

Страница 33: ...pliance 100 000 BTU H 30 KW 12 inches 12 inches M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or paved driveway located on public property 7 feet 7 feet P clearance under veranda porch deck or balcony 22 inches to combustibles 16 inches to non combustibles 22 inches to combustibles 16 inches to non combustibles Q clearance above roof 2 feet 2...

Страница 34: ...ompanies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligati...

Страница 35: ...ght of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve ...

Страница 36: ...XG0237 150204 H42DF ST Residential Gas Fireplace ...