EC Plus-4 Series B-Vent
®
Part No. XG0303C
Installation
Wiring
Gas Control and Pilot Wiring
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junction Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grnd Screw
Figure 6.
Wiring for the EP28-I with Honeywell gas control and pilot.
EP-28-4-I
Optional Blower Kit
EP-28
Series.decorative.fireplaces.may.be.equipped.with.an.optional.
blower.kit
(Part #FAN-28)
for.circulating.heat.into.the.living.space.
Refer to Fan-28 Installation Instructions for more information.
Installations in Canada
.which.employ.the.fan.kit,.must.be.in.accord-
ance.with.
CSA C22.1
.Canadian.Electrical.Code.Part.1.and/or.Local.
Codes.
Installations in the USA
.employ.the.fan.kit,.must.be.in.accordance.
with.local.codes.or,.in.the.absence.of.local.codes,.with.the.National.
Electrical.Code,.
ANSI/NFPA 70-1987.
NOTE:
If any of the original wire supplied with the appli-
ance is replaced, it must be replaced with the same
type, or its equivalent.
Figure 7.
Wiring schematic for optional blower kit.
Supply
WH
BLK
Fan Switch
G
L1 L
Spill