Note:
After the gas line is connected,
each
appliance connection
,
valve and valve train
must be checked while
under normal operating pressure with either a liquid solution, or leak detection device, to locate any source of
leak. Tighten any areas where bubbling appears or where a leak is detected until bubbling stops completely
or leak is no longer detected.
DO NOT use a flame of any kind to test for leaks.
Bk
R
W
Inlet Pressure
Check
Manifold
Pressure
Check
Section 9: Installing the Gas Line
For Your Safety - READ BEFORE LIGHTING:
Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the Fire De-
partment.
C.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system, and
any gas control which has been under water.
A.
This appliance is equipped with an ignition system that lights
the pilot burner automatically.
Do not attempt to light the
pilot by hand.
B. BEFORE LIGHTING
smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
in your building.
WARNING!
If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
The gas connection is located on the underside of the firepit body. The manufacturer requires a service shut off valve lo
-
cated in an accessible location to isolate the fireplace’s gas supply. We reccommend placing this behind your intake grate
for easy access.The gas line must be installed, and tested for leaks before finishing the Custom Firepit.
Natural Gas
requires a minimum inlet gas supply pressure of 5.5" wc, and a manifold pressure of 3.5" wc.
Propane
requires a minimum inlet gas supply pressure of 11" wc, and a manifold pressure of 10" wc.
Maximum inlet pressure is
1/2
PSI for both NG and Propane.
The manifold outlet pressure is set from the factory to the appropriate pressure and should be verified. The control valves
have a provision to remove a
1/8
"
plug so that a hose barb fitting can be installed to check pressure.
Fig 13: Gas Connection Location
*6" vent height recommended for ease of access but
not required
6" *
Fig 12: Gas Valve
Page 11