background image

Page 7

C38-VF Gas Fireplace

Part No. XG0317

WARNING:

 

If you do not follow these instructions exactly, a fire or explosion 

may result causing property damage, personal injury or loss of life.

partment.

C.

  Use only your hand to push in or turn the gas control knob. 

Never use tools. If  the knob will not push in or turn by hand, 

don't try to repair it, call a qualified service technician. Force 

or attempt to repair may result in a fire or explosion.

D.

  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system, and 

any gas control which has been under water.

A.

  This appliance has a pilot which must be lit by hand. When 

lighting the pilot, follow these instructions exactly.

B.  BeFOre lIgHtINg

 smell all around the appliance area for 

gas. Be sure to smell next to the floor because some gas is 

heavier than air and will settle on the floor.

 

What to Do If You Smell gas:

  Do not try to light any appliance.

  Do not touch any electrical switch; do not use any phone 

in your building.

  Immediately call your gas supplier from a neighbour's 

phone. Follow the gas supplier's instructions.

  If you cannot reach your gas supplier, call the Fire De-

To Turn Off Gas To Appliance:

Operating Instructions

3.

  Push in gas control knob slightly and turn  

  clockwise 

to "off".  Do not force.

4.

  Flip up the lower trim.

1.

  Turn off remote switch.

2.

  Flip down the lower trim.

1.

 

StOP!  

Read the safety information above on this label.

2.

  Flip down the lower trims.

3.

  Push in gas control knob and turn clockwise 

  to "oFF."

4.

  Wait five (5) minutes to clear out any gas. Smell for gas, 

including near the floor. If you then smell gas, 

StOP!

 Follow 

"B" in the safety information above on this label. If you don't 

smell gas, go to the next step.

5.

  Locate pilot burner 

(See illustration at right.)

 and follow 

steps below.

6.

  Turn knob on gas control counterclockwise  

  to "PI-

LoT."

7.

  Push in gas control knob completely and hold. Light with 

Piezo Igniter button. Continue to hold the control knob in for 

about (1) minute after the pilot is lit. Release the knob and it 

will pop back up. Pilot should remain lit. If it goes out repeat 

steps 3 through 8.

  If knob does not pop up when released. Stop and im-

mediately call your service technician or gas supplier.

  If the pilot will not stay lit after several tries, turn the gas 

control knob to "oFF" and call your service technician or 

gas supplier.

8.

  Push in gas control 

knob and turn coun-

terclockwise  

  to 

"oN."

9.

  Flip up the lower trim.

10.

 Turn on remote switch to ignite fire.

Lighting  Instructions:

For Your Safety - READ BEFORE LIGHTING:

Gas Control Knob

(Shown in "Pilot" postion.)

NOTE:

  Knob cannot be turned from 

"PILOT" to "OFF" unless knob is 

pushed in slightly.  Do not force.

Содержание C38-VF

Страница 1: ... exactly a fire or explosion may result causing property damage personal injury or loss of life For Your Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate com bustion and ventilation air must be provided Refer ...

Страница 2: ...or servicing an ap pliance must be replaced prior to operating the heater Installationandrepairshouldbedonebyaqualifiedservice person The appliance should be inspected before use and at least annually by a professional service person Morefrequentcleaningmayberequiredduetoexcessive lint from carpeting bedding material etc It is imperative that control compartments burners and air circulating WARNIN...

Страница 3: ... fireplace to a combusti ble ceiling within the fireplace enclosure Refer to page 5 Unprotected combustible walls which are perpendicular to the fire place opening must fall within the limits outlined in Figure 7b For protection against freezing temperatures it is recommended that outer walls of the chase be insulated with a vapour barrier This will reduce the possibility of a cold air convection ...

Страница 4: ...s own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 13 for wiring requirements Note The switch location must not exceed 30 from the fireplace Figure 6 Gas line access The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures i...

Страница 5: ...D IN ANY WAY to do so restricts the air supply for the control compartments and heat exchanger it also prevents access for servicing controls The face of the fireplace may be painted to match the room decor provided you use a heat resistant paint Decorative facing must not extend past the fireplace opening at all because it will interfere with the access to retainers for removal of screen door Fig...

Страница 6: ...e installing the door To re install the door tilt the top edge towards you and line up the tabs of the bottom of the door with the slots on the fireplace Place the tabs into the slots and tilt the top of the door back towards the fireplace as far as it will go Close the latches by hooking Part B onto the groove at the top of the door and pushing Part A down completely Figure 8b Removing the door I...

Страница 7: ...Operating Instructions 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower trim 1 Turn off remote switch 2 Flip down the lower trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you ...

Страница 8: ...d service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Operating Instructions Lighting Instructions See page 7 Burner Adjustment The C38 VF is equipped with an adjustable burner allowing you to raise or lower the flames To adjust the flames locate the black knob marked Hi Lo in the centre of the gas control valve S...

Страница 9: ...nections are faulty Check wiring diagram figure 11 Main burner will 1 Check wiring see figure 11 not light 2 Check wall switch for proper con nection Figure 13a Wiring for optional air circulating fan kit Wiring for the optional Fan Kit All C38 VF fireplaces may be equipped with an optional fan kit Part no RFK1002 or RFK1003 for circulating heat into the living space Kits are available with manual...

Страница 10: ...roduct If they can not supply original replacement part s Call toll free at 1 800 378 3115 Canadian Heating Products Montigo Delray Corp 27342 Gloucester Way Langley BC V4W 4A1 When contacting dealer or Montigo please have the following ready Your name and address Part number and description of part or acces sories to be replaced Model and serial numbers of your heaters Type of Gas used Natural Ga...

Страница 11: ...g from the use of any components not manufactured or supplied by Montigo DelRay Corp 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liab...

Страница 12: ...XG0317 Rev 0 9 2002 Installed and Serviced by Montigo Del Ray Corp 6955 Salashan Parkway 27342 Gloucester Way Ferndale WA 98248 Langley BC ...