Montigo C38-BV Скачать руководство пользователя страница 10

Page 10

C38-BV Gas Fireplace

Part  No.  XG0314

Maintenance

WARNING:

Do not attempt to clean glass when hot.

Do not clean glass with abrasive materials as any glass
etching may cause premature glass failure.

CAUTIONS

n

Fireplace gas control must be in the “OFF” position and pilot
and main burners extinguished when cleaning appliance with
a vacuum.

n

Doors and logs can get very hot. Handle only when cool.

General

n

Have the fireplace installation inspected yearly, including a visual
check of the vent system, the burner and the pilot flame. For your
convenience a 1/8" manifold pressure tap is supplied on the gas
valve for a test gauge connection. See Figure 12.

n

For 

Natural Gas

 this appliance requires a minimum inlet pressure

of 5.5" W.C. and a manifold pressure of 3.5" W.C.

n

For 

Propane Gas 

this appliance requires a minimum inlet pressure

of  11" W.C. and a manifold pressure of 10" W.C.

n

Always keep the fireplace area clear and free of combustible
materials,  as  well  as  gasoline  and  other  flammable  vapours  and
liquids.

n

Do not use this appliance if 

any part has been under water

.

Immediately  call  a  qualified  service  technician  to  inspect  the
appliance  and  to  replace  any  part  of  the  control  system  and  any
gas  control  which  has  been  under  water.

Operation

Lighting Instructions

See pages 8 and 9.

Burner Adjustment

The C38-BV is equipped with an adjustable burner, allowing you to
raise or lower the flames. To adjust the flames, locate the black knob
marked 'Hi-Lo', in the centre of the gas control valve (See Figure 11).
The front burners are not adjustable.

n

To raise the flame height, turn the black knob (located behind the
lower trim) 

counterclockwise

.

n

To lower the flame height, turn 

clockwise

.

Figure 11.

'Hi-Lo' Adjustment on the C38-BV's gas valve.

Cleaning

When the fireplace is first activated, there may be some smoking and a
visible film may be left on the glass. This is a normal condition, and is
the result of burning of protective coatings on new metal.

n

Glass must be cleaned periodically to remove any film (which is a
normal biproduct of combustion) which may be visible. Film can
easily be removed by removing the door, as shown on page 6-7.
Handle the door carefully, and clean it with non-abrasive glass
cleaners. One of the most effective products is Kel Kem.

n

Silicone seals on inner door during initial firing will "off gas", leaving
a visual deposit of a white substance on combustion chamber walls.
This can easily be removed using normal household products.

n

Use a vacuum cleaner or whisk broom to keep the control
compartment,  burner,  and  firebox  free  from  dust  and  lint.

n

Logs  may  be  cleaned  periodically  with  a  vacuum  to  remove
soot  or  other  contaminates.

Note:

C38-BV-I  models  (electronic  ignition)  do  not  feature
hi/lo  adjustment.

Содержание C38-BV

Страница 1: ...Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier For Your Safety Do not store or use gasoline or other flamma...

Страница 2: ...s instructed in this manual ConsultyourlocalGasInspectionBranchoninstallationrequirements for factory built gas fireplaces Installation repairs should be done by aqualifiedcontractor Installations in Canada must conform to the current CAN CGA B 149 1 and 2 Gas Installation Code and local regulations Installations in the USA must conform to local codes or in the absense of local codes to the Nation...

Страница 3: ...ded area shown in Figure 6b For protection against freezing temperatures it is recommended that outer walls of the chase be insulated with a vapour barrier This will reduce the possibility of a cold air convection current on the fireplace Figure 1 Fireplace dimensions Installing a Shelf Over the Fireplace When installing a shelf over the top of the fireplace the minimum allowable clearance from th...

Страница 4: ...ind the lower brass trim may be connected to a wall switch The valve generates its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 12 for wiring requirements Note The switch location must not exceed 30 from the fireplace Figure 5 Gas line access Theapplianceanditsindividualshutoffvalvemustbedisconnected from the gas supply pipi...

Страница 5: ...6a Combustible mantles and facings Mantels Surrounds NOTE National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials New technology to meet consumer and government demands for the wise use of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Please be aware temperatures over the mantel wil...

Страница 6: ...ure 9b Removing the door Removing and Installing the Door Removing the Door Remove the trim as described on the next page to access the door latches Open the latches by pulling Part A upwards and towards you to disengage Part B from the door Lift Part B clear of the door Repeat for all three latches Be sure to hold the door carefully so it does not fall See figure 9a Figure 9a Operating the door l...

Страница 7: ...affle should rest on top of the tabs Inset Slide in baffle beforeinstallingtoptrim Installing the Log Set Installing the Logs The C38 BV is supplied with five ceramic fibre logs Unpack the logs and handle them very carefully 1 Remove the door cover and the glass door 2 Place the Back log onto the back log rest as shown below in figure 10a Theloghasliponthebottomwhichfitsintotheslotonthelogrest 3 P...

Страница 8: ... Model C38 BV 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower trim 1 Turn off remote switch 2 Flip down the lower trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you then smel...

Страница 9: ...ight any appliance n Do not touch any electrical switch do not use any phone in your building n Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down the lower trim 3 Turn the switch on the gas control to Off 4 Flip up the trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Turn ...

Страница 10: ...tions See pages 8 and 9 Burner Adjustment The C38 BV is equipped with an adjustable burner allowing you to raise or lower the flames To adjust the flames locate the black knob marked Hi Lo in the centre of the gas control valve See Figure 11 The front burners are not adjustable n To raise the flame height turn the black knob located behind the lower trim counterclockwise n To lower the flame heigh...

Страница 11: ... SV9600 Check Transformer Line Volt Supply Replace SV9500 SV9600 Save old Igniter Flame Rod Assembly for service INSET HSI Terminals CHECK Line voltage power Low voltage transformer Limit Controller Thermostat Wiring Air proving switch on combustion air blower system Vent damper if used is open and end switch made C38 BV I Gas Control Valve Figure 12 Sit Nova 820 gas valve Pilot Burner Adjustment ...

Страница 12: ...olid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty under any other warranty expres...

Страница 13: ...Page 13 C38 BV Gas Fireplace Part No XG0314 Notes ...

Страница 14: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0314 Rev 1 April 10 01 ...