Cautions and Warnings

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70), including 

fire-rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
After making

 

the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side 

of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed 

carefully up into the outlet box.

WARNING:

 Before you begin installing, servicing or cleaning the fan unit, switch the power off at the service panel and lock the service panel to prevent 

the power from being switched back on accidentally. If the service panel cannot be locked to prevent the power from being switched on accidentally, 

securely fasten a warning sign to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor 

to the trailing edge of the blade.

WARNING:

 To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or 

less” and use mounting screws provided with the outlet box.

CAUTION

: Comply with local codes and regulations. If installing the secondary support safety cable in the U.S., do not remove knockouts in the outlet 

box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the building structure or the ceiling joist.

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert 

foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. JY1126R manufactured by Satellite 

Electronic (Zhongshan) Ltd. 

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment 

manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for 

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing the light kit.

CAUTION:

 The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the 

product should be returned to an authorized service facility for examination or repair.  
All set screws must be checked and tightened where necessary before installation.

Note

: Suitable for use in wet locations when installed in a GFCI protected branch circuit. 

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, FOLLOW THESE INSTRUCTIONS.

Содержание Edge Coastal 60

Страница 1: ...Total fan weight 5 8 kg 12 76 lbs Edge Outdoor Ceiling Fan cETL Model NO 3EGR60XX RH...

Страница 2: ...kouts in the outlet box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of per...

Страница 3: ...n to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remove the 2 outlet box screws provided with t...

Страница 4: ...oles and install cross pin and keeper pin Insert cross pin through yoke and downrod until point appears on the other side and insert keeper pin on cross pin Pull the downrod up tight against the cross...

Страница 5: ...House Make sure that no filaments are outside of the wire connectors Insert the remote receiver into mounting bracket After making the wire connections the wires should be spread apart with the ground...

Страница 6: ...fore they leak or corrode as this will damage the controller Dispose of the used batteries properly Always keep batteries out of the reach of children Battery cover SET SET 1 0 1 0 1 0 Universal Mode...

Страница 7: ...lation it is still using the factory setting Follow the settings for Learn Mode above to reset 2 If the fan or light isn t working reset power turn the power off then turn the power back on and follow...

Страница 8: ...ing bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this le...

Отзывы: