background image

5

© 2015 Monte Carlo Fan Company

4/25/2015

Installation Instruction (Flushmount)

Remove canopy cover by turning counterclockwise. There are 6 holes 

on the bottom of the canopy, 3 of them are larger. (Fig. 5)  

Thread lead wires and safety cable through canopy. Place canopy over 

yoke, aligning larger holes in canopy with the 3 existing screws on top 

of motor housing. Install 3 screws and 3 lock washers  (these screws 

and lock washers are located in the hardware pack) into the remaining 

holes. Tighten all screws securely. (Fig. 5-1)

To prepare the fan for wiring, hang fan onto mounting bracket by 

sliding the canopy over the mounting bracket hook (

Use one of 

non-slotted holes on the rim of the canopy

). (Fig. 5-2)

Safety Cable Installation

For Canadian installation and for USA fan and light kit combinations 

over 35 lbs, in both flush and downrod modes the safety cable must 

be installed into the house structure beams using 3” lag screws, 

washers and lock washers provided. Make sure that when the safety 

cable is fully extended the lead wires are longer than the cable and no 

stress is placed on the lead wires. (Fig. 6)

Note

: If Installing The Secondary Support Safety Cable in the U.S., Do Not 

Remove Knockouts In The Outlet Box.

 

SAFETY CABLE INSTALLATION

Lag screw

Safety cable

Washer

Lock washer

Fig. 5-1

Fig. 6

Fig. 5-2

yoke

Canopy

Screws 

Canopy

Hook

Lead wires and 

Safety cable

Fig. 5

Canopy cover

Canopy ring

Содержание Centro Max 5CQM52-L Series

Страница 1: ...E OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5CQM52XX L Series Fan UL Model NO AC 552AL 9 1 kgs 20 lbs ...

Страница 2: ...The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between ro...

Страница 3: ...hen the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Fig 1 Before installing this fan make sure the outlet box is properly installed to the house structure To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 lbs Fig 2 Use...

Страница 4: ...ther side and insert keeper pin on cross pin Pull the downrod up tight against the cross pin and then evenly tighten the downrod set screws on motor housing yoke Fig 3 Warning Cross pin and keeper pin must be installed securely failure to install them will result in serious injury Install 4 x 25 watt candelabra base bulbs 25W Max Bulbs included Fig 3 1 Install ball end of downrod into mounting bra...

Страница 5: ...e canopy over the mounting bracket hook Use one of non slotted holes on the rim of the canopy Fig 5 2 Safety Cable Installation For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag screws washers and lock washers provided Make sure that when the safety cable is ...

Страница 6: ...nstallation Partially loosen 2 of the set screws on mounting bracket corresponding to the slotted holes on the canopy upper ring Remove the other 2 set screws Save screws Raise canopy to mounting bracket aligning loosened screws in mounting bracket with slotted holes in canopy Twist canopy to lock Reinstall screws with washers that were previously removed and then tighten all screw securely Lift t...

Страница 7: ...motor using the preinstalled screws Tighten screws securely Repeat this process for remaining blade assemblies Fig 9 Note Tighten blade bracket screws twice a year Switch housing installation and wiring Loosen 2 and remove one set screws from the plate on motor keep screw Attached top switch housing onto the plate on motor aligning its keyhole slots with the set screws on the plate and twist clock...

Страница 8: ...ake sure that canopy mounting bracket or mounting plate are tightened securely to ceiling 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan un...

Страница 9: ...Apr 2015 ...

Отзывы: