background image

© 2011 Monte Carlo Fan Company

1/16/2012

6

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

3.

Make sure forward/reverse switch is pushed firmly either way.  Fan will not operate when

switch is in the middle.

CAUTION:  Make sure main power is turned off.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are

tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each

other or against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.  

DO

NOT USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disap-

pear after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction

box and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level

by selecting a point on the ceiling above the tip of one of the blades. Measure this dis-

tance from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next

blade is positioned for measurement. Repeat for each blade. If all blade levels are not

equal, you can adjust blade levels by the following procedure. To adjust a blade tip down,

insert a washer (not supplied) between the blade and blade holder at the screw closest to

the motor. To adjust a blade tip up, insert washer (not supplied) between the blade and

blade holder at the two screws farthest from the motor.  Reverse the position of the

washer if blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can

redistribute the weight and possibly result in smoother operation.

1.Check wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before entering switch housing.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installa-

tion, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience

any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experi-

encing difficulty in installation, please call our Customer Service Center at the number printed on your

parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service

disconnecting means to prevent power from being switched on accidentally.  When the service

disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a

tag, to the service panel.

Trouble

Suggested Remedy

Содержание 5SIEP

Страница 1: ... to this card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5SI Series Fan Total fan weight UL Model No AC 212 002 18 55 kgs 40 81 lbs ...

Страница 2: ... Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do...

Страница 3: ...his will allow hands free wiring 8 7 Tighten both yoke set screws to further secure downrod For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are lo...

Страница 4: ...nd wire After wiring is conplete gently push wires into junction box with wire nuts pointing upward Refer to point 3 of safety tips 11 House Fan Black White Green Black White Green downrod Green Bracket Blue For control of fan and optional light from wall lo cation follow diagram above NOTE A profes sional electrician is recommended for this type of installation 12 Raise the canopy up and align th...

Страница 5: ...previously removed 22 Twist into locking position and tighten in screw taken out Also tighten 2 other loosened screws 19 Connect male to female connector securely 20 For Light Kit Installation Only Loosen the decorative cover first it will make it easier to loosen the finial cap and switch cover for light kit installation ...

Страница 6: ...e is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Rev...

Страница 7: ...Jan 2012 New format Jun 2013 Update for CUL regulation ...