background image

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

3.Check to make sure the dip switches from the transmitter and receiver are set on the same

frequency.

CAUTION:  Make sure main power is turned off

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each

other or against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.  DO

NOT USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear

after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box

and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure this distance from

blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is posi-

tioned for measurement. Repeat for each blade. If all blade levels are not equal, you can

adjust blade levels by the following procedure. To adjust a blade tip down, insert a washer

(not supplied) between the blade and blade holder at the screw closest to the motor. To

adjust a blade tip up, insert washer (not supplied) between the blade and blade holder at the

two screws farthest from the motor.  Reverse the position of the washer if blades mount from

top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can

redistribute the weight and possibly result in smoother operation.

1.Check wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before entering switch housing.

WARNING: Before attempting to replace the fuse make sure the main power is

turned off to the fan. Replace only with 3 amp fuse. Fuse is in canopy.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation,

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults,

please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty

in installation, please call our Customer Service Center at the number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service dis-

connecting means to prevent power from being switched on accidentally.  When the service dis-

connecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Customer Service Center:

740 S.W. Loop 820, Suite 110

Fort Worth, Texas 76115

1-800-519-4092

Trouble

Suggested Remedy

Содержание 5SCR60BR3

Страница 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5SCR60BR3 Fan READ AND SAVE THESE INSTRUCTIONS Total fan weigh with light ...

Страница 2: ...f fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel an...

Страница 3: ...e with four screws to become a complete mount ing bracket 8 Loosen set screws that holds ball 9 Slide ball down and remove pin save pin for later 10 Install top cover over downrod onto fan body 18 Align hole in downrod with hole in yoke and install cross pin Install downrod into yoke Install keeper into cross pin 13 Tighten 2 downrod set screws and lock nuts 14 Install cage on fan body 15 Install ...

Страница 4: ...re beams using the 3 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires 25 Safety cable installation Safety Cable Lag Screw safety cable 3 lag screw lock washer washer Make wire connections to power source using wire nuts provided Make sure that no filiments are outsi...

Страница 5: ... 1 screw removed and tighten all 3 screws securely 33 Attach blades to motor and tighten screws securely using screws washers and motor pads in hardware packs 31 Loosen 2 screws and remove 1 screw Save screw removed 32 Install all thread into switch housing 36 Remove plug from switch housing 35 Install lockwasher and hex nut pro vided and tighten securely 38 Install finial cap and finial nut onto ...

Страница 6: ...ed and tighten securely 45 Plug connector from fan to connector from switch housing 47 Drop decorative cover ring over light kit 44 Install glass to fitters and then install the light rings to hold glass in place 51 Install 3 x 60 watt E12 base bulbs 52 Remove cover by snaping off from top or bottom Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V 53 Attach cover of r...

Страница 7: ... and hold U L botton To dim Lower lights press and hold D L button To turn off either up or down light press and quickly release either U L or D L button Press button marked REV to reverse the rotation direction of the fan blades Fan speed control but tons Fan on off Light dim mer for up and down lights Fan reverse button 57 Install wall control unit to outlet box using machine screws provided 55 ...

Страница 8: ...To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side...

Страница 9: ...6 21 06 REV 0 New made from 5GMR manual ...

Отзывы: