background image

Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes ANSI/NFPA 70-1999),

including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding con-

ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from

being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7

feet from the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating

blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heat-

ing equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA),

and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such

as a tag, to the service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TOOLS REQUIRED

Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder

Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally.  When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such as a

tag, to the service panel.

Before installing this fan make sure the outlet box is

properly installed to the house structure.  To reduce

the risk of fire, electric shock, or personal injury,

mount to outlet box or supporting system acceptable

for fan support. (Mounting must support at least 35

lbs.)

Use metal outlet box suitable for fan support

(must support 35 lbs). Before attaching fan to

outlet box, ensure the outlet box is securley fas-

tened by at least two points to a structural ceil-

ing member ( a loose box will cause the fan to

wabble).  

Use only the screws provided with

the outlet box.  

Place canopy on downrod. (as

shown)

3

2

1

5

Installation

Loosen the 2 set screws till you can

not feel them on inside of yoke.

4

yoke

Thead leadwires and safety cable

through downrod. (as shown)

6

Содержание 5RH52 Series

Страница 1: ...QUALITY CEILING FANS Ceiling Fan Installation Instructions For 5RH52 Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with light OWNER S MANUAL ...

Страница 2: ...combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heat ing equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cle...

Страница 3: ...o Black or Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual 14 House Fan Blue Black White Green Black White Ground Place downrod into fan yoke 7 Install the keeper to pin 9 Tighten the 2 set screws on the yoke once the downrod is in place 10 Align ...

Страница 4: ...installed screws of light kit plate and remove 1 screw Save removed screw for use later Install 3 x 40 watt Candelabra bulbs 28 23 Attach glass to light fixture 29 Install rubber washer and hex nut to glass to secure in place 30 Check the motor for shipping stabi lizers and remove if present Attach blades using screws and washers pre installed Tighten screws secure ly 19 Loosen 2 screws and remove...

Страница 5: ...Install decorative finial nut to glass to secure in place 31 ...

Страница 6: ... this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measure ment Repeat for each blade If all blade levels are not equal you can adjust blade levels by the fol lowing procedure To adjust a blade tip down insert a washer not supplied between ...

Отзывы: