5

Place blade holders onto blades aligning holes in
blade holder with holes in blade.  Make sure that the
side of the blade you select is facing downward.  In-
stall  3 screws and fiber washers to back side of blade
as shown.  Tighten screws securely. Repeat this
process 4 more times until all blades are assembled.

Install blades to motor using the 10

motor screws provided.  Tighten

screws securely.

26

27

Lift fan to mounting bracket, aligning the “L”

shape holes on the canopy with the screws on

the mounting bracket.  Turn the fan  clockwise

to lock in position.  Re-install the screws re-

moved in the previous step and tighten se-

curely.

25

Remove the all thread studs from the

lower part of the mounting bracket.

Hang fan from mounting bracket by

the hands free hook into a closed

hole on the edge of the Canopy.

Note

: For Canadian mounting refer

to Step #8.

21

Hands free hook

Take 4 screws from hardware pack

and insert 2 one on each side of

bracket to match the L slot screw

holes in canopy.  Keep 2 screws for

later use. 

22

Replace the 3 screws removed and

tighten securely. Check motor for

shipping stabilizers and remove if

present.

20

Place canopy over fan body align-

ing holes.

19

Connect black and blue wire from fan to Black or (Hot)
wire from house.  Connect White wire from Fan to White
(Neutral) wire from house.  Connect Ground leads from
mounting bracket and downrod to Ground lead from
house.  

Refer to Safety Tips section of manual.

23

House

Fan

Blue 

Black

White

Green

Black

White

Ground

Make wire connections to power source using wire nuts
provided.  Make sure that no filiments are outside of
the wirenut. After making the wire connections, the
wires should be spread apart with the grounded con-
ductor and the equipment-grounding conductor on one
side of the outlet box and ungrounded conductor on the
other side of the outlet box.  

24

Содержание 5OR52XXD-L Series

Страница 1: ...card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5OR52XXD L Series Fan Total fan weight with light kit UL Model No AC 552 1 8 11 kgs 17 84 lbs ...

Страница 2: ... Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do...

Страница 3: ...l outlet box suitable for fan support and use only the screws provided with the out let box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is se curely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Use only the screws provided with the outlet box 3 Downrod mount installation Hang assembled fan from the mounting...

Страница 4: ... through the canopy 12 Cover Ring Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 11 Next lift the cover ...

Страница 5: ...he Canopy Note For Canadian mounting refer to Step 8 21 Hands free hook Take 4 screws from hardware pack and insert 2 one on each side of bracket to match the L slot screw holes in canopy Keep 2 screws for later use 22 Replace the 3 screws removed and tighten securely Check motor for shipping stabilizers and remove if present 20 Place canopy over fan body align ing holes 19 Connect black and blue ...

Страница 6: ...turning off the wall switch breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on 31 Remove finial nut finial cap hex nut and rubber washer from fitter 32 Install finial cap and finial nut remove in step 32 threading the pull chains through each of the holes Hand tighten finial nut securely 34 Remove switch housing cap from light fixture by removing hex nut and lock w...

Страница 7: ...e holes on switch housing and twist clockwise until tight 38 Loosen 2 the 2 screws which near the slot and remove one preassem bled screws from switch housing cover Keep screw for later use 36 slot Install plastic plug onto switch hous ing cover Plastic plug provided 37 Re install the screws removed in step 36 Tighten all screws securely 39 ...

Страница 8: ...ure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measure ment Repeat for each blade If all blade levels are not equal you can adjust blade levels by the fol lowing procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up i...

Страница 9: ...Dec 2010 Aircool spec Mar 2012 New format Jul 2013 Update for CUL regulation ...

Отзывы: