background image

5ML52-CUL-ENG

Insert downrod into motor yoke. Next, insert

clevis pin through yoke and downrod and

secure with cotter pin. (see inset)

Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes and standards

(ANSI/NFPA 70-1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding con-

ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such

as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet

from the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating

blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating

equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and

the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such

as a tag, to the service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

Installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TOOLS REQUIRED

Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder

Before you begin installing the fan, Switch power off

at Service panel and lock service disconnecting means

to prevent power from being switched on accidentally.

When the service disconnecting means cannot be

locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

Before installing this fan make sure the outlet

box is properly installed to the house structure.

To reduce the risk of fire, electric shock, or per-

sonal injury, mount to outlet box or supporting

system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Install  the Mountiing Bracket to the Outlet box.

Use only the screws provided with the out-

let box.  

Install canopy and yoke cover over the down-

rod.

3

2

1

4

6

Thread wire through downrod with canopy and

yoke cover assembled.

5

Содержание 5ML52 Series

Страница 1: ...5ML52 CUL ENG Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5ML52 Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight ...

Страница 2: ...ric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the...

Страница 3: ...ction box with wire nuts pointing upward Refer to point 3 of safety tips 11 Black White Green Black White Green downrod Green Bracket Blue For control of fan and optional light from wall location follow diagram above NOTE A profes sional electrician is recommended for this type of installation 12 For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and dow...

Страница 4: ...e ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw ...