Thread wires and safety cable through upper

fan body, canopy, and then the half ball. Install

over the downrod to fan body. Replace pin, pull

up half ball and tighten screw securely.

Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes and standards

(ANSI/NFPA 70-1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding con-

ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such

as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet

from the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating

blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating

equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and

the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such

as a tag, to the service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

Installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TTO

OO

OLLSS R

REEQ

QU

UIIR

REED

D

PPhhiilllliippss SSccrreew

wddrriivveerr      W

Wiirree CCuutttteerrss       PPlliieerrss      SStteepp LLaaddddeerr

Before you begin installing the fan, Switch power off

at Service panel and lock service disconnecting means

to prevent power from being switched on accidentally.

When the service disconnecting means cannot be

locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

Before installing this fan make sure the outlet

box is properly installed to the house structure.

To reduce the risk of fire, electric shock, or per-

sonal injury, mount to outlet box or supporting

system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Install  the Mountiing Bracket to the Outlet box.

Use only the screws provided with the out-

let box.  

Loosen screw holding half ball, slide down ball

and remove pin. Remove the ball. (see inserts)

3

2

1

4

6

Thread wires and safety cable  from fan body

through downrod, insert downrod into motor

yoke, and tighten both yoke screws to secure

downrod. Next insert clevis pin throught yoke

and downrod, then secure with cotter pin. (see

inserts)

5

Содержание 5MAR52 Series

Страница 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5MAR52 Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with light ...

Страница 2: ...r a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and...

Страница 3: ...ches on the Transmitter and the Receiver are set to the same position See Fig 25 for remote operation 9 8 Plug white wire from fan to white wire from light kit Then plug black from fan to black from light kit 17 Loosen the 2 screws with key slots and remove the screw without key slot Take plate and place over the 2 screws with key slots and twist to hold in place Tighten the 3 screws securely hold...

Страница 4: ...machine screws provided 24 Attach front cover to wall control with screws provided 25 Align holes in fan with light kit and use the allen wrench furnished to tighen the 6 screws 20 Align the canopy with the holes in fan and use the furnished allen wrench to tighten the 6 screws if you decide not to use the light kit 21 Attach glass by locating dimples in light kit and aligning it with the groves i...

Страница 5: ...re To adjust a blade tip down insert a washer not sup plied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws far thest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by...

Отзывы: